Your browser doesn't support javascript.
loading
[Determination of 8-methoxypsoralen in mouse plasma by high performance liquid chromatography and its application to pharmacokinetic study].
Wu, T W; Cui, R; Zhang, B X.
Afiliação
  • Wu TW; Department of Occupational and Environmental Health Sciences,Peking University School of Public Health, Beijing 100191, China.
  • Cui R; Department of Occupational and Environmental Health Sciences,Peking University School of Public Health, Beijing 100191, China.
  • Zhang BX; Department of Toxicology, Peking University School of Public Health, Beijing 100191, China.
Beijing Da Xue Xue Bao Yi Xue Ban ; 50(5): 792-796, 2018 Oct 18.
Article em Zh | MEDLINE | ID: mdl-30337737
OBJECTIVE: To establish a high performance liquid chromatography (HPLC) method for the determination of 8-methoxypsoralen (8-MOP) in mouse plasma and apply it to a pharmacokinetic study of 8-MOP. METHODS: 8-MOP was separated on a Waters Symmetry18 column (250 mm × 4.6 mm, 5 µm) and determined by HPLC using isocratic elution, and 5-methoxypsoralen was used as internal standard. The mobile phase consisted of methanol-water (55:45, V/V) at a flow rate of 1.0 mL/min. The excitation and emission wavelength of fluorescence detector were set at 334 nm and 484 nm respectively, and the internal standard method was used for quantitative analysis. In the study, 60 healthy ICR male mice were randomly divided into twelve groups. The mice in control group were administered intragastrically with 1% Tween 80, and the mice in the other eleven groups were administered intragastrically with 8-MOP (40 mg/kg). Plasma concentrations of 8-MOP in the mice at different time points after treatment were determined by HPLC. Pharmacokinetic parameters were calculated by DAS 2.0 software. RESULTS: The calibration curve of 8-MOP was linear with a correlation coefficient of 0.999 3 over the concentration range of 0.05 to 10 mg/L, and the limit of detection was 0.015 mg/L. The average recoveries of 8? MOP at three different concentrations (0.10, 0.50, 2.5 mg/L) were from 92.5% to 100.6%. The intra-day precision of 8-MOP was from 3.3% to 8.2%, while the inter-day precision was from 3.4% to 6.7% at three spiked concentration levels. The extraction recoveries of 8-MOP were from 90.9% to 92.0%, and the plasma samples could be stored at -80°C for 15 days at least at three spiked concentration levels. 8-MOP could be detected in mouse plasma 5 min after intragastrical administration to the mice (1.4 mg/L). The concentration of 8-MOP in the mouse plasma reached a maximum 2 h after administration, and 8-MOP could still be detected 24 h after administration (1.1 mg/L). t1/2 was (39.21±3.65) h, Cmax was (2.31±0.02) mg/L, tmax was (2.00±0.00) h, and AUC0-t was (33.34±1.19) (h×mg)/L. CONCLUSION: The proposed method is accurate and simple,suitable for pharmacokinetics of 8-MOP in mice.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Fármacos Fotossensibilizantes / Metoxaleno Limite: Animals Idioma: Zh Revista: Beijing Da Xue Xue Bao Yi Xue Ban Assunto da revista: MEDICINA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Fármacos Fotossensibilizantes / Metoxaleno Limite: Animals Idioma: Zh Revista: Beijing Da Xue Xue Bao Yi Xue Ban Assunto da revista: MEDICINA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China