Your browser doesn't support javascript.
loading
Measurements of DIII-D poloidal field by fiber-optic pulsed polarimetry.
Kimura, W D; Dhillon, D S; Munaretto, S; Strait, E J; Du, D; Loranger, S; Boisvert, J-S; Kashyap, R.
Afiliação
  • Kimura WD; STI Optronics, Redmond, Washington 98052, USA.
  • Dhillon DS; STI Optronics, Redmond, Washington 98052, USA.
  • Munaretto S; General Atomics, San Diego, California 92186, USA.
  • Strait EJ; General Atomics, San Diego, California 92186, USA.
  • Du D; General Atomics, San Diego, California 92186, USA.
  • Loranger S; Department of Engineering Physics and Department of Electrical Engineering, Polytechnique Montreal, Montreal H3C 3A7, Canada.
  • Boisvert JS; Department of Engineering Physics and Department of Electrical Engineering, Polytechnique Montreal, Montreal H3C 3A7, Canada.
  • Kashyap R; Department of Engineering Physics and Department of Electrical Engineering, Polytechnique Montreal, Montreal H3C 3A7, Canada.
Rev Sci Instrum ; 89(10): 10J102, 2018 Oct.
Article em En | MEDLINE | ID: mdl-30399833
ABSTRACT
A new technique for measuring the spatial and temporal structure of the poloidal field is presented, whereby the magnetic field causes the polarization of light traveling through an optical fiber to rotate via the Faraday effect by an amount proportional to the strength of the field oriented along the fiber. In fiber optic pulsed polarimetry, changes in the polarization of the backscatter light from the fiber are detected, thereby permitting measurement of the field as a function of position along the fiber. In this proof-of-principle experiment, specially prepared single-mode fibers with weak fiber Bragg gratings were installed in the poloidal direction on the outside of the thermal blanket on DIII-D. Light at 532 nm from a mode-locked NdYAG laser was injected into the optical fibers. The laser repetition rate was 895 kHz with a pulse length of <10 ps, resulting in ∼1 µs temporal resolution. A photodetector system measured the Stokes polarization components necessary to determine the amount of polarization rotation. For this experiment, bandwidth limitations of the detectors resulted in a spatial resolution of ≈2 cm. The measured temporal and spatial distributions of the poloidal field are consistent with inductive probe measurements and Elastodynamic Finite Integration Technique reconstructions of the spatial distribution. This demonstrates the ability of this technique to provide real-time detection of the temporal and spatial variations of the poloidal field. Besides revealing more detailed information about the plasma, this new diagnostic capability can also help in detecting instabilities in real time, thereby enabling enhanced machine protection.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos