Your browser doesn't support javascript.
loading
Impact of bladder volume on acute genitourinary toxicity in intensity modulated radiotherapy for localized and locally advanced prostate cancer.
Grün, Arne; Kawgan-Kagan, Michael; Kaul, David; Badakhshi, Harun; Stromberger, Carmen; Budach, Volker; Böhmer, Dirk.
Afiliação
  • Grün A; Department for Radiation Oncology, Charité-University Medicine Berlin, Campus Virchow-Clinic, Augustenburger Platz 1, 13353, Berlin, Germany. arne.gruen@charite.de.
  • Kawgan-Kagan M; Department for Radiation Oncology, Helios Klinikum Berlin-Buch, Schwanebecker Chaussee 50, 13125, Berlin, Germany.
  • Kaul D; Department for Radiation Oncology, Charité-University Medicine Berlin, Campus Virchow-Clinic, Augustenburger Platz 1, 13353, Berlin, Germany.
  • Badakhshi H; Department for Radiation Oncology, Ernst-von-Bergmann Klinikum, Charlottenstraße 72, 14467, Potsdam, Germany.
  • Stromberger C; Department for Radiation Oncology, Charité-University Medicine Berlin, Campus Virchow-Clinic, Augustenburger Platz 1, 13353, Berlin, Germany.
  • Budach V; Department for Radiation Oncology, Charité-University Medicine Berlin, Campus Virchow-Clinic, Augustenburger Platz 1, 13353, Berlin, Germany.
  • Böhmer D; Department for Radiation Oncology, Charité-University Medicine Berlin, Campus Benjamin Franklin, Hindenburgdamm 30, 12203, Berlin, Germany.
Strahlenther Onkol ; 195(6): 517-525, 2019 Jun.
Article em En | MEDLINE | ID: mdl-30443682
BACKGROUND AND PURPOSE: To evaluate the effect of changes in bladder volume during high-dose intensity-modulated-radiotherapy (IMRT) of prostate cancer on acute genitourinary (GU) toxicity and prospectively evaluate a simple biofeedback technique for reproducible bladder filling with the aim of reducing acute GU toxicity. METHODS: One hundred ninety-three patients were trained via a biofeedback mechanism to maintain a partially filled bladder with a reproducible volume of 200-300 cc at planning CT and subsequently at each fraction of radiotherapy. We prospectively analyzed whether and to what extent the patients' ability to maintain a certain bladder filling influenced the degree of acute GU toxicity and whether cut-off values could be differentiated. RESULTS: We demonstrated that the ability to reach a reproducible bladder volume above a threshold volume of 180 cc and maintain that volume via biofeedback throughout treatment predicts for a decrease in acute GU toxicity during curative high-dose IMRT of the prostate. Patients who were not able to reach a partial bladder filling to that cut-off value and were not able to maintain a partially filled bladder throughout treatment had a significantly higher risk of developing ≥grade 2 GU acute toxicity. CONCLUSION: Our results support the hypothesis that a biofeedback training for the patient is an easy-to-apply, useful, and cost-effective tool for reducing acute GU toxicity in high-dose IMRT of the prostate. Patients who are not able to reach and maintain a certain bladder volume during planning and treatment-two independent risk factors-might need special consideration.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Sistema Urogenital / Bexiga Urinária / Radioterapia de Intensidade Modulada Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Humans / Male / Middle aged Idioma: En Revista: Strahlenther Onkol Assunto da revista: NEOPLASIAS / RADIOTERAPIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Sistema Urogenital / Bexiga Urinária / Radioterapia de Intensidade Modulada Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Humans / Male / Middle aged Idioma: En Revista: Strahlenther Onkol Assunto da revista: NEOPLASIAS / RADIOTERAPIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Alemanha