Your browser doesn't support javascript.
loading
Ordinary Optical Fiber Sensor for Ultra-High Temperature Measurement Based on Infrared Radiation.
Lin, Qijing; Zhao, Na; Yao, Kun; Jiang, Zhuangde; Tian, Bian; Shi, Peng; Chen, Feng.
Afiliação
  • Lin Q; Collaborative Innovation Center of High-End Manufacturing Equipment, Xi'an Jiaotong University, Xi'an 710054, China. xjjingmi@163.com.
  • Zhao N; State Key Laboratory of Mechanical Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China. xjjingmi@163.com.
  • Yao K; State Key Laboratory of Mechanical Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China. zn2015@stu.xjtu.edu.cn.
  • Jiang Z; State Key Laboratory of Mechanical Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China. vinsent@stu.xjtu.edu.cn.
  • Tian B; Collaborative Innovation Center of High-End Manufacturing Equipment, Xi'an Jiaotong University, Xi'an 710054, China. zdjiang@mail.xjtu.edu.cn.
  • Shi P; State Key Laboratory of Mechanical Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China. zdjiang@mail.xjtu.edu.cn.
  • Chen F; State Key Laboratory of Mechanical Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China. t.b12@mail.xjtu.edu.cn.
Sensors (Basel) ; 18(11)2018 Nov 21.
Article em En | MEDLINE | ID: mdl-30469408
ABSTRACT
An ordinary optical fiber ultra-high temperature sensor based on infrared radiation with the advantages of simple structure and compact is presented. The sensing system consists of a detection fiber and a common transmission fiber. The detector fiber is formed by annealing a piece of ordinary fiber at high temperature twice, which changes the properties of the fiber and breaks the temperature limit of ordinary fiber. The transmission fiber is a bending insensitive optical fiber. A static calibration system was set up to determine the performance of the sensor and three heating experiments were carried out. The temperature response sensitivities were 0.010 dBm/K, 0.009 dBm/K and 0.010 dBm/K, respectively, which indicate that the sensor has good repeatability. The sensor can withstand a high temperature of 1823 K for 58 h with an error of less than 1%. The main reason why the developed ordinary optical fiber sensor can work steadily for a long time at high temperature is the formation of ß-cristobalite, which is stable at high-temperature.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China