Manipulation of mass transport rates using bead-in-a-tube method.
Uhnak, Nicolas E F; Morrison, Samuel S; O'Hara, Matthew J; Murray, Nathaniel J; Bartsch, Michael S; Edwards, Harrison S; Grate, Jay W.
Afiliação
  • Uhnak NEF; Pacific Northwest National Laboratory: 902 Battelle Blvd., P.O. Box 999, Richland, WA 99354, USA. Electronic address: Nicolas.uhnak@PNNL.gov.
  • Morrison SS; Pacific Northwest National Laboratory: 902 Battelle Blvd., P.O. Box 999, Richland, WA 99354, USA.
  • O'Hara MJ; Pacific Northwest National Laboratory: 902 Battelle Blvd., P.O. Box 999, Richland, WA 99354, USA.
  • Murray NJ; Pacific Northwest National Laboratory: 902 Battelle Blvd., P.O. Box 999, Richland, WA 99354, USA.
  • Bartsch MS; Sandia National Laboratory: Sandia National Laboratories, P.O. Box 969, Livermore, CA, 94550, USA.
  • Edwards HS; Sandia National Laboratory: Sandia National Laboratories, P.O. Box 969, Livermore, CA, 94550, USA.
  • Grate JW; Pacific Northwest National Laboratory: 902 Battelle Blvd., P.O. Box 999, Richland, WA 99354, USA.
J Chromatogr A ; 1586: 139-144, 2019 Feb 08.
Article em En | MEDLINE | ID: mdl-30528768
ABSTRACT
In ultralow Pu analyses, the gold standard is thermal ionization mass spectrometry (TIMS), which requires pure sources to achieve its performance. This purity is achieved through step-wise purifications. In this work single, anion-exchange beads were trapped in the tubing to allow for dynamic solution cycling over the surface of the beads to improve the rates of metal complex uptake. Rates of Pu sorption on single ∼900 µm SIR-1200 and ∼620 µm Reillex-HPQ beads were determined for single beads trapped in a tube with syringe pump driven dynamic solution cycling over the bead, improving sorption and desorption rates. A static control was used as a comparison. Using 238Pu to enable facile activity-based measurements, rates were determined by measuring the residual Pu after contact with beads using liquid scintillation analysis (LSA) for fixed periods of time. Syringe pump driven dynamic solution cycling results in ∼5 and ∼15-fold improvements in the sorption rates for SIR-1200 and Reillex-HPQ. Impacts on desorption were also examined.