Your browser doesn't support javascript.
loading
Reliability of effective arterial elastance using peripheral arterial pressure as surrogate for left ventricular end-systolic pressure.
Monge Garcia, Manuel Ignacio; Jian, Zhongping; Settels, Jos J; Hatib, Feras; Cecconi, Maurizio; Pinsky, Michael R.
Afiliação
  • Monge Garcia MI; Unidad de Cuidados Intensivos, Hospital Universitario SAS de Jerez, C/ Circunvalación, s/n, 11407, Jerez de la Frontera, Spain. ignaciomonge@gmail.com.
  • Jian Z; Edwards Lifesciences, Irvine, CA, USA.
  • Settels JJ; Edwards Lifesciences, Irvine, CA, USA.
  • Hatib F; Edwards Lifesciences, Irvine, CA, USA.
  • Cecconi M; Department Anaesthesia and Intensive Care Units, Humanitas Research Hospital, Humanitas University, Milan, Italy.
  • Pinsky MR; Department Anaesthesia and Intensive Care Units, Humanitas Research Hospital, Humanitas University, Milan, Italy.
J Clin Monit Comput ; 33(5): 803-813, 2019 Oct.
Article em En | MEDLINE | ID: mdl-30552525
ABSTRACT
To compare the effective arterial elastance (Ea) obtained from the arterial pressure with Ea calculated from left-ventricular (LV) pressure-volume analysis. Experimental study. LV pressure-volume data was obtained with a conductance catheter and arterial pressures were measured via a fluid-filled catheter placed in the proximal aorta, femoral and radial arteries. Ea was calculated as LV end-systolic pressure (ESP)/stroke volume (SV). Experimental protocol consisted sequentially changing afterload (phenylephrine/nitroprusside), preload (bleeding/fluid), and contractility (esmolol/dobutamine). 90% of systolic pressure (Eaao_SYS, Eafem_SYS, Earad_SYS), mean arterial pressure (Eaao_MAP, Eafem_MAP, Earad_MAP), and dicrotic notch pressure (Eaao_DIC, Eafem_DIC, Earad_DIC) were used as surrogates for LV ESP. SV was calculated from the LV pressure-volume data. When Ea was compared with estimations based on 90% SAP, the relationship was r2 = 0.95, 0.94 and 0.92; and the bias and limits of agreement (LOA) - 0.01 ± 0.12, - 0.09 ± 0.12, - 0.05 ± 0.15 mmHg ml-1, for Eaao_SYS, Eafem_SYS and Earad_SYS, respectively. For estimates using dicrotic notch, the relationship was r2 = 0.94, 0.95 and 0.94 for Eaao_DIC, Eafem_DIC and Earad_DIC, respectively; with a bias and LOA 0.05 ± 0.11, 0.06 ± 0.12, 0.10 ± 0.12 mmHg ml-1, respectively. When Ea was compared with estimates using MAP, the relationship was r2 = 0.95, 0.96 and 0.95 for Eaao_MAP, Eafem_MAP and Earad_MAP, respectively; with a bias and LOA 0.05 ± 0.11, 0.06 ± 0.11, 0.06 ± 0.11 mmHg ml-1, respectively. LV ESP can be estimated from the arterial pressure. Provided that the SV measurement is reliable, the ratio MAP/SV provides a robust Ea surrogate over a wide range of hemodynamic conditions and is interchangeably in any peripheral artery, so it should be recommended as an arterial estimate of Ea in further research.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sístole / Monitorização Intraoperatória / Pressão Arterial / Ventrículos do Coração Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J Clin Monit Comput Assunto da revista: INFORMATICA MEDICA / MEDICINA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sístole / Monitorização Intraoperatória / Pressão Arterial / Ventrículos do Coração Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J Clin Monit Comput Assunto da revista: INFORMATICA MEDICA / MEDICINA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Espanha