Your browser doesn't support javascript.
loading
Correlation Structure in Micro-ECoG Recordings is Described by Spatially Coherent Components.
Rogers, Nicholas; Hermiz, John; Ganji, Mehran; Kaestner, Erik; Kiliç, Kivilcim; Hossain, Lorraine; Thunemann, Martin; Cleary, Daniel R; Carter, Bob S; Barba, David; Devor, Anna; Halgren, Eric; Dayeh, Shadi A; Gilja, Vikash.
Afiliação
  • Rogers N; Physics, University of California San Diego, La Jolla, CA, United States of America.
  • Hermiz J; Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, United States of America.
  • Ganji M; Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, United States of America.
  • Kaestner E; Department of Neurosciences, University of California San Diego, La Jolla, CA, United States of America.
  • Kiliç K; Department of Neurosciences, University of California San Diego, La Jolla, CA, United States of America.
  • Hossain L; Materials Science and Engineering, NanoEngineering University of California San Diego, La Jolla, CA, United States of America.
  • Thunemann M; Department of Radiology, University of California San Diego, La Jolla, CA, United States of America.
  • Cleary DR; Department of Neurosurgery, University of California San Diego, La Jolla, CA, United States of America.
  • Carter BS; Department of Neurosurgery, University of California San Diego, La Jolla, CA, United States of America.
  • Barba D; Department of Neurosurgery, University of California San Diego, La Jolla, CA, United States of America.
  • Devor A; Department of Radiology, University of California San Diego, La Jolla, CA, United States of America.
  • Halgren E; Department of Neurosciences, University of California San Diego, La Jolla, CA, United States of America.
  • Dayeh SA; Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA, United States of America.
  • Gilja V; Department of Radiology, University of California San Diego, La Jolla, CA, United States of America.
PLoS Comput Biol ; 15(2): e1006769, 2019 02.
Article em En | MEDLINE | ID: mdl-30742605
ABSTRACT
Electrocorticography (ECoG) is becoming more prevalent due to improvements in fabrication and recording technology as well as its ease of implantation compared to intracortical electrophysiology, larger cortical coverage, and potential advantages for use in long term chronic implantation. Given the flexibility in the design of ECoG grids, which is only increasing, it remains an open question what geometry of the electrodes is optimal for an application. Conductive polymer, PEDOTPSS, coated microelectrodes have an advantage that they can be made very small without losing low impedance. This makes them suitable for evaluating the required granularity of ECoG recording in humans and experimental animals. We used two-dimensional (2D) micro-ECoG grids to record intra-operatively in humans and during acute implantations in mouse with separation distance between neighboring electrodes (i.e., pitch) of 0.4 mm and 0.2/0.25 mm respectively. To assess the spatial properties of the signals, we used the average correlation between electrodes as a function of the pitch. In agreement with prior studies, we find a strong frequency dependence in the spatial scale of correlation. By applying independent component analysis (ICA), we find that the spatial pattern of correlation is largely due to contributions from multiple spatially extended, time-locked sources present at any given time. Our analysis indicates the presence of spatially structured activity down to the sub-millimeter spatial scale in ECoG despite the effects of volume conduction, justifying the use of dense micro-ECoG grids.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletrocorticografia Limite: Animals / Humans Idioma: En Revista: PLoS Comput Biol Assunto da revista: BIOLOGIA / INFORMATICA MEDICA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletrocorticografia Limite: Animals / Humans Idioma: En Revista: PLoS Comput Biol Assunto da revista: BIOLOGIA / INFORMATICA MEDICA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Estados Unidos