Your browser doesn't support javascript.
loading
Continuous erythrocyte removal and leukocyte separation from whole blood based on viscoelastic cell focusing and the margination phenomenon.
Nam, Jeonghun; Yoon, Jung; Kim, Jeeyong; Jang, Woong Sik; Lim, Chae Seung.
Afiliação
  • Nam J; Department of Laboratory Medicine, College of Medicine, Korea University, Korea University Guro Hospital, Guro 2-Dong, Guro-Gu, Seoul, 152-703, Republic of Korea; Department of Emergency Medicine, College of Medicine, Korea University, 80, Guro-dong, Guro-gu, Seoul, 152-703, Republic of Korea. Elect
  • Yoon J; Department of Laboratory Medicine, College of Medicine, Korea University, Korea University Guro Hospital, Guro 2-Dong, Guro-Gu, Seoul, 152-703, Republic of Korea.
  • Kim J; Department of Laboratory Medicine, College of Medicine, Korea University, Korea University Guro Hospital, Guro 2-Dong, Guro-Gu, Seoul, 152-703, Republic of Korea.
  • Jang WS; Department of Laboratory Medicine, College of Medicine, Korea University, Korea University Guro Hospital, Guro 2-Dong, Guro-Gu, Seoul, 152-703, Republic of Korea; Department of Emergency Medicine, College of Medicine, Korea University, 80, Guro-dong, Guro-gu, Seoul, 152-703, Republic of Korea.
  • Lim CS; Department of Laboratory Medicine, College of Medicine, Korea University, Korea University Guro Hospital, Guro 2-Dong, Guro-Gu, Seoul, 152-703, Republic of Korea. Electronic address: malarim@korea.ac.kr.
J Chromatogr A ; 1595: 230-239, 2019 Jun 21.
Article em En | MEDLINE | ID: mdl-30772054
ABSTRACT
The removal of erythrocytes from whole blood is an essential step during sample preparations intended for biomedical analyses and clinical diagnoses. To address the limitations of present methods, such as centrifugation and chemical lysis, we propose a novel microfluidic device for erythrocyte removal with high-efficiency and leukocyte separation from bulk flows of highly concentrated erythrocytes using a viscoelastic non-Newtonian fluid. The proposed device is designed based on the principle of viscoelasticity-induced particle migration toward the center of the microchannel. In addition, we based the functionality of our device on a bio-inspired phenomenon known as margination according to which erythrocytes migrate to the axial center of blood vessels. Fluorescent particles (10 µm) were added to blood suspensions of various concentrations (hematocrit) of erythrocytes in viscoelastic polymer solutions. Optimal hematocrit and flow rate conditions were determined for erythrocyte removal and for the separation of 10 µm particles. We also demonstrated the capability of our device to separate leukocytes with high efficiency (˜94%) and with a high-enrichment factor (10-fold).
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Separação Celular / Eritrócitos / Dispositivos Lab-On-A-Chip / Leucócitos Limite: Humans Idioma: En Revista: J Chromatogr A Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Separação Celular / Eritrócitos / Dispositivos Lab-On-A-Chip / Leucócitos Limite: Humans Idioma: En Revista: J Chromatogr A Ano de publicação: 2019 Tipo de documento: Article