In vitro retention efficiency of temporary type zinc oxide cement for orthodontic forced eruption.
Int Orthod
; 17(1): 96-102, 2019 03.
Article
em En
| MEDLINE
| ID: mdl-30772354
OBJECTIVE: To assess the retention efficiency of three types of temporary zinc oxide cement trademarks on forced eruption using intracranal wire device. METHODS: An in vitro evaluation included intracanal wire device displacement and detachment at 50g load force for 120 days and then the retention resistance at maximum load force. RESULTS: All groups of temporary zinc oxide cements were efficient to support 50g load forces after 120 days. None statistical differences were found between groups. Zinc oxide cements supported a maximum retention load force, which exceeded in more than 84 times the lowest value obtained in controls (420g). CONCLUSION: Zinc oxide cements are efficient to retain intracanal wire devices on forced eruption processes in vitro and allows removal of both when necessary (wire device and cement, respectively).
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Óxido de Zinco
/
Cimentos de Resina
/
Cimentos Dentários
/
Extrusão Ortodôntica
Limite:
Humans
Idioma:
En
Revista:
Int Orthod
Assunto da revista:
ORTODONTIA
Ano de publicação:
2019
Tipo de documento:
Article