Your browser doesn't support javascript.
loading
In Vivo High-resolution Ratiometric Fluorescence Imaging of Inflammation Using NIR-II Nanoprobes with 1550 nm Emission.
Wang, Shangfeng; Liu, Lu; Fan, Yong; El-Toni, Ahmed Mohamed; Alhoshan, Mansour Saleh; Li, Dandan; Zhang, Fan.
Afiliação
  • Wang S; Department of Chemistry, State Key Laboratory of Molecular Engineering of Polymers, Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials and iChem , Fudan University , Shanghai 200433 , P. R. China.
  • Liu L; Department of Chemistry, State Key Laboratory of Molecular Engineering of Polymers, Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials and iChem , Fudan University , Shanghai 200433 , P. R. China.
  • Fan Y; Department of Chemistry, State Key Laboratory of Molecular Engineering of Polymers, Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials and iChem , Fudan University , Shanghai 200433 , P. R. China.
  • El-Toni AM; King Abdullah Institute for Nanotechnology , King Saud University , Riyadh 11451 , Saudi Arabia.
  • Alhoshan MS; Department of Chemical Engineering , King Saud University , Riyadh 11421 , Saudi Arabia.
  • Li D; Department of Chemistry, State Key Laboratory of Molecular Engineering of Polymers, Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials and iChem , Fudan University , Shanghai 200433 , P. R. China.
  • Zhang F; Department of Chemistry, State Key Laboratory of Molecular Engineering of Polymers, Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials and iChem , Fudan University , Shanghai 200433 , P. R. China.
Nano Lett ; 19(4): 2418-2427, 2019 04 10.
Article em En | MEDLINE | ID: mdl-30883136
ABSTRACT
Quantitatively imaging the spatiotemporal distribution of biological events in living organisms is essential to understand fundamental biological processes. Self-calibrating ratiometric fluorescent probes enable accurate and reliable imaging and sensing, but conventional probes using wavelength of 400-900 nm suffer from extremely low resolution for in vivo application due to the disastrous photon scattering and tissue autofluorescence background. Here, we develop a NIR-IIb (1500-1700 nm) emissive nanoprobe for high-resolution ratiometric fluorescence imaging in vivo. The obtained nanoprobe shows fast ratiometric response to hypochlorous acid (HOCl) with a detection limit down to 500 nM, through an absorption competition-induced emission (ACIE) bioimaging system between lanthanide-based downconversion nanoparticles and Cy7.5 fluorophores. Additionally, we demonstrate the superior spatial resolution of 1550 nm to a penetration depth of 3.5 mm in a scattering tissue phantom, which is 7.1-fold and 2.1-fold higher than that of 1064 and 1344 nm, respectively. With this nanoprobe, clear anatomical structures of lymphatic inflammation in ratiometric channel are observed with a precise resolution of ∼477 µm. This study will motivate the further research on the development of NIR-II probes for high-resolution biosensing in vivo.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas / Imagem Óptica / Inflamação Limite: Humans Idioma: En Revista: Nano Lett Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas / Imagem Óptica / Inflamação Limite: Humans Idioma: En Revista: Nano Lett Ano de publicação: 2019 Tipo de documento: Article