Your browser doesn't support javascript.
loading
Multicenter Registry about the Use of EndoAnchors in the Endovascular Repair of Abdominal Aortic Aneurysms with Hostile Neck Showed Successful but Delayed Endograft Sealing within Intraoperative Type Ia Endoleak Cases.
Reyes Valdivia, Andrés; Beropoulis, Efthymios; Pitoulias, Georgios; Pratesi, Giovanni; Alvarez Marcos, Francisco; Barbante, Matteo; Gandarias, Claudio; Torsello, Giovanni; Bisdas, Theodosios; Donas, Konstantinos.
Afiliação
  • Reyes Valdivia A; Department of Vascular and Endovascular Surgery, Ramón y Cajals University Hospital, Madrid, Spain. Electronic address: cauzaza@hotmail.com.
  • Beropoulis E; Department of Vascular Surgery, St Franziskus Hospital Münster, Clinic for Vascular and Endovascular Surgery, Münster University Hospital, Münster, Germany.
  • Pitoulias G; Department of Surgery, Gennimatas Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece.
  • Pratesi G; Vascular Surgery Unit, Department of Biomedicine and Prevention, University of Rome Tor Vergata, Rome, Italy.
  • Alvarez Marcos F; Department of Vascular and Endovascular Surgery, Juan Canalejo's University Hospital, A Coruña, Spain.
  • Barbante M; Vascular Surgery Unit, Department of Biomedicine and Prevention, University of Rome Tor Vergata, Rome, Italy.
  • Gandarias C; Department of Vascular and Endovascular Surgery, Ramón y Cajals University Hospital, Madrid, Spain.
  • Torsello G; Department of Vascular Surgery, St Franziskus Hospital Münster, Clinic for Vascular and Endovascular Surgery, Münster University Hospital, Münster, Germany.
  • Bisdas T; Department of Vascular Surgery, St Franziskus Hospital Münster, Clinic for Vascular and Endovascular Surgery, Münster University Hospital, Münster, Germany.
  • Donas K; Department of Vascular Surgery, St Franziskus Hospital Münster, Clinic for Vascular and Endovascular Surgery, Münster University Hospital, Münster, Germany.
Ann Vasc Surg ; 60: 61-69, 2019 Oct.
Article em En | MEDLINE | ID: mdl-31028850
BACKGROUND: The durability of endovascular aortic aneurysms repair (EVAR) is highly related to several anatomical constraints. The term "hostile neck" describes several anatomical features that usually make EVAR treatment technically demanding despite having higher risk of failure. The aim of the study was to describe a multicenter experience with EVAR and an adjunctive use of EndoAnchors in hostile neck anatomies. METHODS: Data were prospectively collected from 4 academic vascular centers including 46 patients with a hostile neck treated by standard EVAR with the adjunctive use of EndoAnchors. Twenty-two of them (47.8%, group A) had an intraoperative type Ia endoleak, and 24 (52.2%) patients were treated in a preventive manner (group B). Primary endpoints were technical and procedural success. Secondary endpoints were regression of the aneurysm sac, freedom from type Ia endoleak, and reinterventions. RESULTS: Neck length and diameter showed no statistical difference in preoperative measures, 9.1 ± 6.9 mm and 8.6 ± 2.8 mm and 25.4 ± 4.7 mm and 27.3 ± 4.7 mm, in group A and B, respectively. Aneurysm sac diameter decreased from 58.2 ± 8 mm and 57.9 ± 9.8 mm to 55.7 ± 8.5 mm and 53.8 ± 10.4 mm in group A and B; respectively, at the last computed tomography scan. Technical and procedural success was 97.8% and 100%, respectively, for group B. Group A showed persistence of type Ia endoleak at completion angiogram in 9 (40.9%) patients. Five of them showed early spontaneous sealing at the first (30 days) computed tomography angiography (CTA), and in the remaining 4, a delayed spontaneous sealing was diagnosed at 12-month CTA. No neck-related secondary procedures were performed. Overall survival was 91%. CONCLUSIONS: Our study shows that additional use of EndoAnchors can successfully improve the sealing of abdominal endografts in case of intraoperative type Ia endoleaks in hostile neck anatomies, representing a safe and effective endovascular alternative in our armamentarium. However, meticulous radiological follow-up is necessary because complete resolution of all observed intraoperative type Ia endoleaks was not observed until the 12-month CTA follow-up.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prótese Vascular / Aneurisma da Aorta Abdominal / Implante de Prótese Vascular / Endoleak / Procedimentos Endovasculares Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: Ann Vasc Surg Assunto da revista: ANGIOLOGIA Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prótese Vascular / Aneurisma da Aorta Abdominal / Implante de Prótese Vascular / Endoleak / Procedimentos Endovasculares Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: Ann Vasc Surg Assunto da revista: ANGIOLOGIA Ano de publicação: 2019 Tipo de documento: Article