Decontamination of Personal Protective Equipment.
Lemmer, Karin; Pauli, Georg; Howaldt, Sabine; Schwebke, Ingeborg; Mielke, Martin; Grunow, Roland.
Afiliação
  • Lemmer K; Dr. Karin Lemmer is a scientist in the Unit Highly Pathogenic Microorganisms, Centre for Biological Threats and Special Pathogens; Professor Georg Pauli is the former Head of the Centre for Biological Threats and Special Pathogens; Sabine Howaldt is a medical technical assistant in the Unit Highly P
  • Pauli G; Dr. Karin Lemmer is a scientist in the Unit Highly Pathogenic Microorganisms, Centre for Biological Threats and Special Pathogens; Professor Georg Pauli is the former Head of the Centre for Biological Threats and Special Pathogens; Sabine Howaldt is a medical technical assistant in the Unit Highly P
  • Howaldt S; Dr. Karin Lemmer is a scientist in the Unit Highly Pathogenic Microorganisms, Centre for Biological Threats and Special Pathogens; Professor Georg Pauli is the former Head of the Centre for Biological Threats and Special Pathogens; Sabine Howaldt is a medical technical assistant in the Unit Highly P
  • Schwebke I; Dr. Karin Lemmer is a scientist in the Unit Highly Pathogenic Microorganisms, Centre for Biological Threats and Special Pathogens; Professor Georg Pauli is the former Head of the Centre for Biological Threats and Special Pathogens; Sabine Howaldt is a medical technical assistant in the Unit Highly P
  • Mielke M; Dr. Karin Lemmer is a scientist in the Unit Highly Pathogenic Microorganisms, Centre for Biological Threats and Special Pathogens; Professor Georg Pauli is the former Head of the Centre for Biological Threats and Special Pathogens; Sabine Howaldt is a medical technical assistant in the Unit Highly P
  • Grunow R; Dr. Karin Lemmer is a scientist in the Unit Highly Pathogenic Microorganisms, Centre for Biological Threats and Special Pathogens; Professor Georg Pauli is the former Head of the Centre for Biological Threats and Special Pathogens; Sabine Howaldt is a medical technical assistant in the Unit Highly P
Health Secur ; 17(3): 200-212, 2019.
Article em En | MEDLINE | ID: mdl-31173501
Exploratory field analyses of the inactivation capacity of disinfectants on contaminated personal protective equipment (PPE) are required to select a suitable surrogate for biohazardous agents like spores of Bacillus anthracis. The objectives of our study were (1) the determination of an appropriate surrogate for the inactivation of spores of B. anthracis with peracetic acid (PAA), and (2) application of optimized inactivation conditions for an effective decontamination of PPE with PAA under field conditions. For inactivation studies, B. anthracis spores from different strains and B. thuringiensis spores were fixed by air drying on carriers prepared from PPE fabric. Time and concentration studies with PAA-based disinfectants revealed that the spores of the B. thuringiensis strain DSM 350 showed an inactivation profile comparable to that of the spores of the B. anthracis strain with the highest stability, implying that B. thuringiensis can serve as an appropriate surrogate. Rapid (3 to 5 minutes) and effective surface decontamination was achieved with 2% PAA/0.2% surfactant. In field studies, PPE contaminated with spores of B. thuringiensis was treated with the disinfectant. Optimizing the decontamination technique revealed that spraying in combination with brushing was effective within 5 minutes of exposure.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bacillus anthracis / Bacillus thuringiensis / Descontaminação / Equipamento de Proteção Individual Idioma: En Revista: Health Secur Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bacillus anthracis / Bacillus thuringiensis / Descontaminação / Equipamento de Proteção Individual Idioma: En Revista: Health Secur Ano de publicação: 2019 Tipo de documento: Article