Your browser doesn't support javascript.
loading
SPECT/CT imaging of apoptosis in aortic aneurysm with radiolabeled duramycin.
Hu, Chengkai; Tan, Hui; Lin, Qingyu; Abudupataer, Mieradilijiang; Zhao, Yun; Li, Jun; Gu, Jiawei; Cheng, Dengfeng; Wang, Chunsheng; Zhu, Kai; Lai, Hao.
Afiliação
  • Hu C; Department of Cardiac Surgery, Zhongshan Hospital, Fudan University, 1609 Xietu Road, Shanghai, 200032, China.
  • Tan H; Shanghai Institute of Cardiovascular Diseases, Shanghai, 200032, China.
  • Lin Q; Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, China.
  • Abudupataer M; Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China.
  • Zhao Y; Shanghai Institute of Medical Imaging, Shanghai, 200032, China.
  • Li J; Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, China.
  • Gu J; Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China.
  • Cheng D; Shanghai Institute of Medical Imaging, Shanghai, 200032, China.
  • Wang C; Department of Cardiac Surgery, Zhongshan Hospital, Fudan University, 1609 Xietu Road, Shanghai, 200032, China.
  • Zhu K; Shanghai Institute of Cardiovascular Diseases, Shanghai, 200032, China.
  • Lai H; Department of Cardiac Surgery, Zhongshan Hospital, Fudan University, 1609 Xietu Road, Shanghai, 200032, China.
Apoptosis ; 24(9-10): 745-755, 2019 10.
Article em En | MEDLINE | ID: mdl-31227933
ABSTRACT
The objective of this research was to estimate whether a [99mTc]duramycin probe can be used for apoptosis imaging in patients with aortic aneurysm (AA). Vascular smooth muscle cell (SMC) apoptosis has an important influence on AA development. Thus, non-invasive imaging of SMC apoptosis may be able to evaluate AA progress and risk stratification. SMCs were treated with hydrogen peroxide (H2O2; 200 µΜ) or culture medium as a control. Apoptosis was measured using flow cytometry and [99mTc]duramycin to detect the binding efficiency to apoptotic SMCs. C57/BL6 mice were administered angiotensin-II and beta-aminopropionitrile (BAPN) subcutaneously to establish an AA model, or saline for controls. Aortic specimens underwent pathological evaluation and their aortic diameters were measured after 6 weeks. Micro-SPECT/CT scanning of [99mTc]duramycin and 18F-FDG PET detection were performed. SMCs treated with H2O2 showed more apoptosis compared with the control group (67.2 ± 3.8% vs. 16.1 ± 0.6%, P < 0.01). The experimental group showed a high rate of AA formation (70%) compared with no AA formation in the control group. The average aorta diameter was higher and [99mTc]duramycin uptake at the AA site was higher in the experimental group compared with the control group. Compared with the normal aorta in the control group, AA in experiment group had more severe medial degeneration, elastic fiber reduction and fracture, and collagen degeneration. TUNEL staining verified the higher apoptosis rate at the AA site in experiment group compared with the control group (63.9 ± 3.7% in ascending AA, 66.4 ± 4.0% in thoracic AA, vs. 3.5 ± 0.3% in normal aorta, P < 0.01). [99mTc]Duramycin may be an effective probe to evaluate apoptosis in AA.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma Aórtico / Tomografia Computadorizada de Emissão de Fóton Único / Apoptose / Marcação por Isótopo Limite: Animals / Humans / Male Idioma: En Revista: Apoptosis Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma Aórtico / Tomografia Computadorizada de Emissão de Fóton Único / Apoptose / Marcação por Isótopo Limite: Animals / Humans / Male Idioma: En Revista: Apoptosis Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China