Your browser doesn't support javascript.
loading
An ultrasensitive fluorescence sensor for determination of trace levels of copper in blood samples.
Vojoudi, Hossein; Bastan, Bahareh; Ghasemi, Jahan B; Badiei, Alireza.
Afiliação
  • Vojoudi H; School of Chemistry, College of Science, University of Tehran, Tehran, 14174, Iran.
  • Bastan B; Department of Chemistry, Faculty of Science, Central Tehran Branch, Islamic Azad University, Shahrak Gharb, Tehran, 13185, Iran.
  • Ghasemi JB; School of Chemistry, College of Science, University of Tehran, Tehran, 14174, Iran.
  • Badiei A; School of Chemistry, College of Science, University of Tehran, Tehran, 14174, Iran. abadiei@khayam.ut.ac.ir.
Anal Bioanal Chem ; 411(21): 5593-5603, 2019 Aug.
Article em En | MEDLINE | ID: mdl-31289896
A novel SBA-15-based fluorescent sensor, SBA-PI: mesoporous SBA-15 structure modified with iminostilbene groups, was designed, synthesized, and characterized by Fourier transform-infrared spectroscopy (FT-IR), ultraviolet-visible spectroscopy, field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDS), thermogravimetric analysis (TGA), low-angle X-ray diffraction techniques (low-angle XRD), and N2 adsorption-desorption techniques. The SBA-PI as a sensor with a selective behavior for detection of Cu2+ comprises iminostilbene carbonyl as the fluorophore group. The SBA-PI sensor displays an excellent fluorescence response in aqueous solutions and the fluorescence intensity quenches remarkably upon addition of Cu2+. Other common interfering ions even at high concentration ratio showed either no or very small changes in the fluorescence intensity of SBA-PI in the absence of Cu2+. A limit of detection of 8.7 × 10-9 M for Cu2+ indicated that this fluorescence sensor has a high sensitivity and selectivity toward the target copper (II) ion. The fabricated Cu2+ sensor was successfully applied for the determination of the Cu2+ in human blood samples without any significant interference. With the selective analysis of Cu2+ ions down to 0.9 nM in blood, the sensor is a promising and a novel detection candidate for Cu2+ and can be applied in the clinical laboratory. A reversibility and accuracy in the fluorescence behavior of the sensor was found in the presence of I¯ that was described as a masking agent for Cu2+. Graphical abstract.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oligoelementos / Espectroscopia de Infravermelho com Transformada de Fourier / Cobre Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Irã

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oligoelementos / Espectroscopia de Infravermelho com Transformada de Fourier / Cobre Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Irã