Your browser doesn't support javascript.
loading
Quantification of Opioids in Urine Using an Aptamer-Based Free-Solution Assay.
Kammer, Michael N; Kussrow, Amanda; Gandhi, Ilavarasi; Drabek, Rafal; Batchelor, Robert H; Jackson, George W; Bornhop, Darryl J.
Afiliação
  • Kammer MN; Department of Chemistry and Vanderbilt Institute of Chemical Biology , Vanderbilt University , Nashville , Tennessee 37235 , United States.
  • Kussrow A; Department of Chemistry and Vanderbilt Institute of Chemical Biology , Vanderbilt University , Nashville , Tennessee 37235 , United States.
  • Gandhi I; Base Pair Biotechnologies, Inc. , Pearland , Texas 77584 , United States.
  • Drabek R; Base Pair Biotechnologies, Inc. , Pearland , Texas 77584 , United States.
  • Batchelor RH; Base Pair Biotechnologies, Inc. , Pearland , Texas 77584 , United States.
  • Jackson GW; Base Pair Biotechnologies, Inc. , Pearland , Texas 77584 , United States.
  • Bornhop DJ; Department of Chemistry and Vanderbilt Institute of Chemical Biology , Vanderbilt University , Nashville , Tennessee 37235 , United States.
Anal Chem ; 91(16): 10582-10588, 2019 08 20.
Article em En | MEDLINE | ID: mdl-31314489
The opioid epidemic continues in the United States. Many have been impacted by this epidemic, including neonates who exhibit Neonatal Abstinence Syndrome (NAS). Opioid diagnosis and NAS can be negatively impacted by limited testing options outside the hospital, due to poor assay performance, false-negatives, rapid drug clearance rates, and difficulty in obtaining enough specimen for testing. Here we report a small volume urine assay for oxycodone, hydrocodone, fentanyl, noroxycodone, norhydrocodone, and norfentanyl with excellent LODs and LOQs. The free-solution assay (FSA), coupled with high affinity DNA aptamer probes and a compensated interferometric reader (CIR), represents a potential solution for quantifying opioids rapidly, at high sensitivity, and noninvasively on small sample volumes. The mix-and-read test is 5- to 275-fold and 50- to 1250-fold more sensitive than LC-MS/MS and immunoassays, respectively. Using FSA, oxycodone, hydrocodone, fentanyl, and their urinary metabolites were quantified using 10 µL of urine at 28-81 pg/mL, with >95% specificity and excellent accuracy in ∼1 h. The assay sensitivity, small sample size requirement, and speed could enable opioid screening, particularly for neonates, and points to the potential for pharmacokinetic tracking.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aptâmeros de Nucleotídeos / Analgésicos Opioides Limite: Humans Idioma: En Revista: Anal Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aptâmeros de Nucleotídeos / Analgésicos Opioides Limite: Humans Idioma: En Revista: Anal Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Estados Unidos