Your browser doesn't support javascript.
loading
Analysis of thrombin-antithrombin complex formation using microchip electrophoresis and mass spectrometry.
Nielsen, Jacob B; Nielsen, Anna V; Carson, Richard H; Lin, Hsien-Jung L; Hanson, Robert L; Sonker, Mukul; Mortensen, Daniel N; Price, John C; Woolley, Adam T.
Afiliação
  • Nielsen JB; Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA.
  • Nielsen AV; Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA.
  • Carson RH; Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA.
  • Lin HL; Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA.
  • Hanson RL; Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA.
  • Sonker M; Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA.
  • Mortensen DN; Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA.
  • Price JC; Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA.
  • Woolley AT; Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA.
Electrophoresis ; 40(21): 2853-2859, 2019 11.
Article em En | MEDLINE | ID: mdl-31373007
ABSTRACT
Preterm birth (PTB) related health problems take over one million lives each year, and currently, no clinical analysis is available to determine if a fetus is at risk for PTB. Here, we describe the preparation of a key PTB risk biomarker, thrombin-antithrombin (TAT), and characterize it using dot blots, MS, and microchip electrophoresis (µCE). The pH for fluorescently labeling TAT was also optimized using spectrofluorometry and spectrophotometry. The LOD of TAT was measured in µCE. Lastly, TAT was combined with six other PTB risk biomarkers and separated in µCE. The ability to make and characterize TAT is an important step toward the development of an integrated microfluidic diagnostic for PTB risk.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeo Hidrolases / Espectrometria de Massas / Antitrombina III / Eletroforese em Microchip Limite: Humans Idioma: En Revista: Electrophoresis Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeo Hidrolases / Espectrometria de Massas / Antitrombina III / Eletroforese em Microchip Limite: Humans Idioma: En Revista: Electrophoresis Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Estados Unidos