Your browser doesn't support javascript.
loading
Reexamination of Accelerometer Calibration with Energy Expenditure as Criterion: VO2net Instead of MET for Age-Equivalent Physical Activity Intensity.
Arvidsson, Daniel; Fridolfsson, Jonatan; Buck, Christoph; Ekblom, Örjan; Ekblom-Bak, Elin; Lissner, Lauren; Hunsberger, Monica; Börjesson, Mats.
Afiliação
  • Arvidsson D; Center for Health and Performance, Department of Food and Nutrition, and Sport Science, University of Gothenburg, 40530 Gothenburg, Sweden. daniel.arvidsson@gu.se.
  • Fridolfsson J; Center for Health and Performance, Department of Food and Nutrition, and Sport Science, University of Gothenburg, 40530 Gothenburg, Sweden.
  • Buck C; Department of Biometry and Data Management, Leibniz Institute for Prevention Research and Epidemiology-BIPS, 28359 Bremen, Germany.
  • Ekblom Ö; Åstrand Laboratory of Work Physiology, Swedish School of Sport and Health Sciences, 11486 Stockholm, Sweden.
  • Ekblom-Bak E; Åstrand Laboratory of Work Physiology, Swedish School of Sport and Health Sciences, 11486 Stockholm, Sweden.
  • Lissner L; Department of Public Health and Community Medicine, Sahlgrenska Academy, University of Gothenburg, 40530 Gothenburg, Sweden.
  • Hunsberger M; Department of Public Health and Community Medicine, Sahlgrenska Academy, University of Gothenburg, 40530 Gothenburg, Sweden.
  • Börjesson M; Center for Health and Performance, Department of Food and Nutrition, and Sport Science, University of Gothenburg, 40530 Gothenburg, Sweden.
Sensors (Basel) ; 19(15)2019 Aug 01.
Article em En | MEDLINE | ID: mdl-31374854
Accelerometer calibration for physical activity (PA) intensity is commonly performed using Metabolic Equivalent of Task (MET) as criterion. However, MET is not an age-equivalent measure of PA intensity, which limits the use of MET-calibrated accelerometers for age-related PA investigations. We investigated calibration using VO2net (VO2gross - VO2stand; mL⋅min-1⋅kg-1) as criterion compared to MET (VO2gross/VO2rest) and the effect on assessment of free-living PA in children, adolescents and adults. Oxygen consumption and hip/thigh accelerometer data were collected during rest, stand and treadmill walk and run. Equivalent speed (Speedeq) was used as indicator of the absolute speed (Speedabs) performed with the same effort in individuals of different body size/age. The results showed that VO2net was higher in younger age-groups for Speedabs, but was similar in the three age-groups for Speedeq. MET was lower in younger age-groups for both Speedabs and Speedeq. The same VO2net-values respective MET-values were applied to all age-groups to develop accelerometer PA intensity cut-points. Free-living moderate-and-vigorous PA was 216, 115, 74 and 71 min/d in children, adolescents, younger and older adults with VO2net-calibration, but 140, 83, 74 and 41 min/d with MET-calibration, respectively. In conclusion, VO2net calibration of accelerometers may provide age-equivalent measures of PA intensity/effort for more accurate age-related investigations of PA in epidemiological research.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Descanso / Exercício Físico / Metabolismo Energético / Acelerometria Tipo de estudo: Health_economic_evaluation / Prognostic_studies Limite: Adolescent / Adult / Child / Female / Humans / Male Idioma: En Revista: Sensors (Basel) Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Suécia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Descanso / Exercício Físico / Metabolismo Energético / Acelerometria Tipo de estudo: Health_economic_evaluation / Prognostic_studies Limite: Adolescent / Adult / Child / Female / Humans / Male Idioma: En Revista: Sensors (Basel) Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Suécia