Your browser doesn't support javascript.
loading
MRI detection of cerebral microbleeds: size matters.
Haller, Sven; Scheffler, Max; Salomir, Rares; Herrmann, François R; Gold, Gabriel; Montandon, Marie-Louise; Kövari, Enikö.
Afiliação
  • Haller S; Faculty of Medicine, University of Geneva, Geneva, Switzerland. sven.haller@me.com.
  • Scheffler M; Department of Surgical Sciences, Radiology, Uppsala University, Uppsala, Sweden. sven.haller@me.com.
  • Salomir R; Department of Radiology, University Hospitals of Geneva, Geneva, Switzerland.
  • Herrmann FR; Department of Radiology, University Hospitals of Geneva, Geneva, Switzerland.
  • Gold G; Department of Rehabilitation and Geriatrics, University Hospitals of Geneva, Geneva, Switzerland.
  • Montandon ML; Department of Rehabilitation and Geriatrics, University Hospitals of Geneva, Geneva, Switzerland.
  • Kövari E; Department of Rehabilitation and Geriatrics, University Hospitals of Geneva, Geneva, Switzerland.
Neuroradiology ; 61(10): 1209-1213, 2019 Oct.
Article em En | MEDLINE | ID: mdl-31396662
ABSTRACT

PURPOSE:

Cerebral microbleeds (CMB) play an important role as an imaging biomarker notably in vascular and neurodegenerative diseases. Current clinical brain MRI underestimates the number of CMB with respect to histopathology. It is expected that small CMBs are more likely to be false-negatives, yet this has not been demonstrated and the average size of false-negative and true-positive CMBs have not been established.

METHODS:

The radiologic-histopathologic correlation study was approved by the local review board and included 42 consecutive cases (mean age at death, 80.7 ± 10.0 years; 23 females and 19 men) between 12 January 2012 and 10 December 2012 having undergone brain autopsy. Postmortem SWI (susceptibility-weighted imaging) images were acquired on a clinical 3T system using parameters similar to clinical routine. The detection of CMB on postmortem MRI was compared with corresponding histopathological slices.

RESULTS:

Postmortem MRI detected 23 true-positive CMB. Histopathology additionally detected 68 CMBs (false-negative MRI CMBs). The average size true-positive MRI CMBs had on histopathology was 3.6 ± 7.1 mm3. The average size false-negative MRI CMBs was significantly smaller (p < 0.05), measuring 0.3 ± 1.2 mm3 on histopathology.

CONCLUSION:

Size matters. As expected, the average size of true-positive MRI CMB was around 10 times larger as compared with false-negative MRI CMB. Evidently, in addition to size, other factors will influence the detectability of CMB, including iron content, ratio of Fe2+/Fe3+, spatial configuration, and location, yet this remains to be elucidated in future studies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Hemorragia Cerebral Tipo de estudo: Diagnostic_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Neuroradiology Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Hemorragia Cerebral Tipo de estudo: Diagnostic_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Neuroradiology Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Suíça