End-expiratory occlusion test predicts fluid responsiveness in cardiac surgical patients in the operating theatre.
Xu, Li-Ying; Tu, Guo-Wei; Cang, Jing; Hou, Jun-Yi; Yu, Ying; Luo, Zhe; Guo, Ke-Fang.
Afiliação
  • Xu LY; Department of Anesthesiology, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
  • Tu GW; Department of Crit Care Med, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
  • Cang J; Department of Anesthesiology, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
  • Hou JY; Department of Crit Care Med, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
  • Yu Y; Department of Anesthesiology, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
  • Luo Z; Department of Crit Care Med, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
  • Guo KF; Department of Crit Care Med, Xiamen Branch, Zhongshan Hospital, Fudan University, Xiamen 361015, China.
Ann Transl Med ; 7(14): 315, 2019 Jul.
Article em En | MEDLINE | ID: mdl-31475185
ABSTRACT

BACKGROUND:

The aim of this study was to evaluate whether a 20-second end-expiratory occlusion (EEO) test can predict fluid responsiveness in cardiac surgery patients in the operating theatre.

METHODS:

This prospective study enrolled 75 mechanically ventilated patients undergoing elective coronary artery bypass grafting surgery. Hemodynamic data coupled with transesophageal echocardiography monitoring of the velocity time integral (VTI) and the peak velocity (Vmax) at the left ventricular outflow tract were collected at each step (baseline 1, EEO, baseline 2 and fluid challenge). Patients were divided into fluid responders (increase in VTI ≥15%) and non-responders (increase in VTI <15%) after a fluid challenge (6 mL 0.9% saline per kg, given in 10 minutes).

RESULTS:

Fluid challenge significantly increased the VTI by more than 15% in 36 (48%) patients (responders). An increase in VTI greater than 5% during the EEO test predicted fluid responsiveness with a sensitivity of 81% and a specificity of 93%. The area under the receiver-operating characteristic curve (AUROC) of ΔVTI-EEO was 0.90 [95% confidence interval (CI) 0.83-0.97]. ΔVmax-EEO was poorly predictive of fluid responsiveness, with an AUC of 0.75 (95% CI 0.63-0.86).

CONCLUSIONS:

Changes in VTI induced by a 20-second EEO can reliably predict fluid responsiveness in cardiac surgical patients in the operating theatre, whereas the changes in Vmax cannot.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Ann Transl Med Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Ann Transl Med Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China