Your browser doesn't support javascript.
loading
A beneficial technique for preventing the device protrusion to the aorta during percutaneous patent ductus arteriosus closure: "Balloon-assisted device releasing technique".
Epçaçan, Serdar; Bulut, Mustafa Orhan; Yücel, Ilker Kemal; Çelebi, Ahmet.
Afiliação
  • Epçaçan S; Department of Paediatric Cardiology, Van Training and Research Hospital, University of Health Sciences, Van, Turkey.
  • Bulut MO; Department of Paediatric Cardiology, Dr. Siyami Ersek Hospital for Cardiology and Cardiovascular Surgery, University of Health Sciences, Istanbul, Turkey.
  • Yücel IK; Department of Paediatric Cardiology, Dr. Siyami Ersek Hospital for Cardiology and Cardiovascular Surgery, University of Health Sciences, Istanbul, Turkey.
  • Çelebi A; Department of Paediatric Cardiology, Dr. Siyami Ersek Hospital for Cardiology and Cardiovascular Surgery, University of Health Sciences, Istanbul, Turkey.
Cardiol Young ; 29(11): 1380-1386, 2019 Nov.
Article em En | MEDLINE | ID: mdl-31502534
ABSTRACT

BACKGROUND:

Although percutaneous closure of patent ductus arteriosus is an established safe procedure, protrusion of the device to descending aorta may occur in various degrees during these procedures, especially in small infants. The aim of our study is to evaluate the benefits of balloon-assisted device releasing technique in the era of preventing device protrusion and conditions related to protrusion.

METHODS:

One hundred and fifty-five infants, who underwent patent ductus arteriosus closure with Amplatzer duct occluder I device between January, 2012 and December, 2018, were retrospectively analysed. Balloon-assisted device releasing technique was used in 20 cases (group 1, 12.9%), between January, 2015 and December, 2018. Procedures in which the technique had been used were compared with the remaining ones (group 2, 87.1%, n = 135) with regard to device stabilisation, aortic disc protrusion to the aorta, iatrogenic coarctation, and device embolisation.

RESULTS:

There was no significant difference by means of gender, age, weight, and the ductal diameter, whereas the average mean pulmonary artery pressure was significantly higher in group 1. Device protrusion and related complications were significantly higher in group 2; thus, additional catheterisations or surgical interventions were required, while no additional intervention was required in group 1.

CONCLUSION:

The balloon-assisted device releasing technique provides a good device stabilisation and prevents protrusion of the device and related complications during percutaneous patent ductus arteriosus closure in selected cases.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aorta Torácica / Cateterismo Cardíaco / Oclusão com Balão / Permeabilidade do Canal Arterial / Dispositivo para Oclusão Septal / Lesões do Sistema Vascular / Complicações Intraoperatórias Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies Limite: Female / Humans / Infant / Male Idioma: En Revista: Cardiol Young Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / PEDIATRIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Turquia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aorta Torácica / Cateterismo Cardíaco / Oclusão com Balão / Permeabilidade do Canal Arterial / Dispositivo para Oclusão Septal / Lesões do Sistema Vascular / Complicações Intraoperatórias Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies Limite: Female / Humans / Infant / Male Idioma: En Revista: Cardiol Young Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / PEDIATRIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Turquia