Your browser doesn't support javascript.
loading
Novel Solid-State Potentiometric Sensors Using Polyaniline (PANI) as A Solid-Contact Transducer for Flucarbazone Herbicide Assessment.
Kamel, Ayman H; Amr, Abd El-Galil E; Abdalla, Nashwa S; El-Naggar, Mohamed; Al-Omar, Mohamed A; Alkahtani, Hamad M; Sayed, Ahmed Y A.
Afiliação
  • Kamel AH; Department of Chemistry, Faculty of Science, Ain Shams University, Abbasia 11566, Cairo, Egypt. ahkamel76@sci.asu.edu.eg.
  • Amr AEE; Pharmaceutical Chemistry Department, Drug Exploration & Development Chair (DEDC), College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia. aamr@ksu.edu.sa.
  • Abdalla NS; Applied Organic Chemistry Department, National Research Center, Dokki 12622, Giza, Egypt. aamr@ksu.edu.sa.
  • El-Naggar M; Department of Chemistry, Faculty of Science, Ain Shams University, Abbasia 11566, Cairo, Egypt. anoooosh311@gmail.com.
  • Al-Omar MA; Chemistry Department, Faculty of Sciences, University of Sharjah, Sharjah 27272, UAE. m5elnaggar@yahoo.com.
  • Alkahtani HM; Pharmaceutical Chemistry Department, Drug Exploration & Development Chair (DEDC), College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia. malomar1@ksu.edu.sa.
  • Sayed AYA; Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia. ahamad@ksu.edu.sa.
Polymers (Basel) ; 11(11)2019 Nov 01.
Article em En | MEDLINE | ID: mdl-31683994
ABSTRACT
Novel potentiometric solid-contact ion-selective electrodes (SC/ISEs) based on molecularly imprinted polymers (MIPs) as sensory carriers (MIP/PANI/ISE) were prepared and characterized as potentiometric sensors for flucarbazone herbicide anion. However, aliquat S 336 was also studied as a charged carrier in the fabrication of Aliquat/PANI/ISEs for flucarbazone monitoring. The polyaniline (PANI) film was inserted between the ion-sensing membrane (ISM) and the electronic conductor glassy carbon substrate (GC). The sensors showed a noticeable response towards flucarbazone anions with slopes of -45.5 ± 1.3 (r2 = 0.9998) and -56.3 ± 1.5 (r2 = 0.9977) mV/decade over the range of 10-2-10-5, 10-2-10-4 M and detection limits of 5.8 × 10-6 and 8.5 × 10-6 M for MIP/PANI/ISE and Aliguat/PANI/ISE, respectively. The selectivity and long-term potential stability of all presented ISEs were investigated. The short-term potential and electrode capacitances were studied and evaluated using chronopotentiometry and electrochemical impedance spectrometry (EIS). The proposed ISEs were introduced for the direct measurement of flucarbazone herbicide in different soil samples sprayed with flucarbazone herbicide. The results agree well with the results obtained using the standard liquid chromatographic method (HPLC).
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Polymers (Basel) Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Egito

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Polymers (Basel) Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Egito