Your browser doesn't support javascript.
loading
Novel spectrofluorimetric quantification of alogliptin benzoate in biofluids exploiting its interaction with 4-chloro-7-nitrobenzofurazan.
Aref, Heba A; Hammad, Sherin F; Darwish, Khaled M; Elgawish, Mohammed S.
Afiliação
  • Aref HA; Department of Medicinal Chemistry, Faculty of Pharmacy, University of El Mounufia, El Mounufia, Egypt.
  • Hammad SF; Department of Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, Egypt.
  • Darwish KM; Department of Medicinal Chemistry, Faculty of Pharmacy, Suez Canal University, Ismailia, Egypt.
  • Elgawish MS; Department of Medicinal Chemistry, Faculty of Pharmacy, Suez Canal University, Ismailia, Egypt.
Luminescence ; 35(2): 284-291, 2020 Mar.
Article em En | MEDLINE | ID: mdl-31762136
ABSTRACT
The direct determination of alogliptin benzoate (ALO) using fluorescence has not yet been accomplished because ALO cannot fluoresce naturally. Accordingly, it should be derivatized first with a fluorogenic reagent to enhance the sensitivity required for its bioanalysis. This method is the first spectrofluorimetric assay for ALO quantification exploiting the nucleophilic nature of its amino group to react with 4-chloro-7-nitrobenzofurazan (NBD-Cl) in borate buffer at pH 8.5 to produce a strong fluorescent compound that is excited at and emits at wavelengths 470 and 527 nm, respectively. Experimental variables concerning the conditions of reaction and fluorogenic intensity were carefully investigated and optimized. Linearity was from 1-250 ng ml-1 with a lower detection limit of 0.29 ng ml-1 and a lower quantification limit of 0.88 ng ml-1 . Validation of the current study was accomplished with mean per cent recovery of 100.62 ± 1.59 in tablets and 99.86 ± 0.82 in human plasma. Furthermore, the current method has been utilized in the bioanalysis of ALO in real rat plasma after oral administration with a simple specimen preparation. The developed method has proven to be a promising alternative method for ALO analysis in bioequivalence studies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Piperidinas / Espectrometria de Fluorescência / Uracila / Benzoatos / Corantes Fluorescentes / 4-Cloro-7-nitrobenzofurazano Limite: Animals / Humans / Male Idioma: En Revista: Luminescence Assunto da revista: BIOFISICA / BIOQUIMICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Egito

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Piperidinas / Espectrometria de Fluorescência / Uracila / Benzoatos / Corantes Fluorescentes / 4-Cloro-7-nitrobenzofurazano Limite: Animals / Humans / Male Idioma: En Revista: Luminescence Assunto da revista: BIOFISICA / BIOQUIMICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Egito