Quality of life of patients undergoing conventional vs leadless pacemaker implantation: A multicenter observational study.
Cabanas-Grandío, Pilar; García Campo, Enrique; Bisbal, Felipe; García-Seara, Javier; Pachón, Marta; Juan-Salvadores, Pablo; Paredes, Emilio; Molinero, Asier; Martínez-Sande, José Luis; Arias, Miguel Ángel; Íñiguez Romo, Andrés.
Afiliação
  • Cabanas-Grandío P; Cardiology Department, Hospital Álvaro Cunqueiro, Vigo, Pontevedra, Spain.
  • García Campo E; Cardiology Department, Hospital Álvaro Cunqueiro, Vigo, Pontevedra, Spain.
  • Bisbal F; Cardiology Department, Hospital Germans Trias i Pujol, Badalona, Spain.
  • García-Seara J; Cardiology Department, Hospital Clínico Universitario, Santiago de Compostela, Spain.
  • Pachón M; Cardiology Department, Hospital Virgen de la Salud, Toledo, Spain.
  • Juan-Salvadores P; Cardiology Department, Hospital Álvaro Cunqueiro, Vigo, Pontevedra, Spain.
  • Paredes E; Cardiology Department, Hospital Álvaro Cunqueiro, Vigo, Pontevedra, Spain.
  • Molinero A; Cardiology Department, Hospital Germans Trias i Pujol, Badalona, Spain.
  • Martínez-Sande JL; Cardiology Department, Hospital Clínico Universitario, Santiago de Compostela, Spain.
  • Arias MÁ; Cardiology Department, Hospital Virgen de la Salud, Toledo, Spain.
  • Íñiguez Romo A; Cardiology Department, Hospital Álvaro Cunqueiro, Vigo, Pontevedra, Spain.
J Cardiovasc Electrophysiol ; 31(1): 330-336, 2020 01.
Article em En | MEDLINE | ID: mdl-31840881
ABSTRACT

BACKGROUND:

Leadless pacemakers (L-PM) are an emerging effective and safe technology that offer an alternative to conventional pacemakers (C-PM) for right ventricular stimulation. However, there is little information about their potential benefits for quality of life (QoL) in patients with L-PM. We compared QoL between patients with L-PM and C-PM.

METHODS:

The study population comprised patients undergoing single chamber pacemaker implantation from December 2016 to March 2018. The SF-36 questionnaire was used to evaluate QoL at baseline and at 6 months of followup. We also used a questionnaire consisted of 10 specific questions related to the implant procedure.

RESULTS:

A total of 106 patients (64 C-PM; 42 L-PM) were included. There were no differences in baseline characteristics between the groups (C-PM vs L-PM), except for age (81.5 vs 77.3 years; P = .012) and diabetes (38% vs 17%; P = .021). Baseline SF-36 scores did not differ between the groups. At 6 months followup, patients in the L-PM group scored significantly higher on physical function (63 vs 42; P < .001), physical role (64 vs 36; P = .004), and mental health (75 vs 65; P = .017), even after adjusting for covariates. Pacemaker-related discomfort and physical restrictions were significantly lower for the L-PM group.

CONCLUSION:

L-PM is associated with better QoL than C-PM in both physical and mental health. Patients undergoing L-PM implantation reported less procedure-related discomfort, physical restriction, and preoccupation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Arritmias Cardíacas / Qualidade de Vida / Estimulação Cardíaca Artificial Tipo de estudo: Clinical_trials / Diagnostic_studies / Observational_studies Limite: Aged / Aged80 / Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: J Cardiovasc Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Arritmias Cardíacas / Qualidade de Vida / Estimulação Cardíaca Artificial Tipo de estudo: Clinical_trials / Diagnostic_studies / Observational_studies Limite: Aged / Aged80 / Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: J Cardiovasc Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Espanha