Your browser doesn't support javascript.
loading
Poly(3,4-ethylenedioxythiophene) Bearing Pyridylboronic Acid Group for Specific Recognition of Sialic Acid.
Hai, Wenfeng; Pu, Sihua; Wang, Xia; Bao, Liming; Han, Narenchaoketu; Duan, Limei; Liu, Jinghai; Goda, Tatsuro; Wu, Wenming.
Afiliação
  • Goda T; Institute of Biomaterials and Bioengineering , Tokyo Medical and Dental University (TMDU) , 2-3-10 Kanda-Surugadai, Chiyoda , Tokyo 101-0062 , Japan.
  • Wu W; State Key Laboratory of Applied Optics, Chuangchun Institute of Optics, Fine Mechanics and Physics , Chinese Academy of Sciences , Changchun 130033 , China.
Langmuir ; 36(2): 546-553, 2020 01 21.
Article em En | MEDLINE | ID: mdl-31849232
ABSTRACT
Conducting polymers tethered with molecular recognition elements are good candidates for biosensing applications such as detecting a target molecule with selectivity. We develop a new monomer, namely, 3,4-ethylenedioxythiophene bearing a pyridylboronic acid moiety (EDOT-PyBA), for label-free detection of sialic acid as a cancer biomarker. PyBA, which is known to show specific binding to sialic acid in acid conditions is used as a synthetic ligand instead of lectins. PyBA confirms the enhanced binding affinity for sialic acid at pH 5.0-6.0 compared with traditional phenylboronic acid. Poly(EDOT-PyBA) is electrodeposited on a planar glassy carbon electrode and the obtained film is successfully characterized by X-ray photoelectron spectroscopy, scanning electron microscopy, atomic force microscopy, water contact angle measurements, and electrochemical impedance spectroscopy. The specific interaction of PyBA with sialic acid at the solution/electrode interface is detected by differential pulse voltammetry in a dynamic range 0.1-3.0 mM with a detection limit of 0.1 mM for a detection time of 3 min. The sensitivity covers the total level of free sialic acid in human serum and the assay time is the shorter than that of other methods. The poly(EDOT-PyBA) electrode successfully detects spiked sialic acid in human serum samples. Owing to its processability, mass productivity, and robustness, polythiophene conjugated with "boronolectin" is a candidate material for developing point-of-care and wearable biosensors.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Langmuir Assunto da revista: QUIMICA Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Langmuir Assunto da revista: QUIMICA Ano de publicação: 2020 Tipo de documento: Article