Your browser doesn't support javascript.
loading
Direct quantitation of tenofovir diphosphate in human blood with mass spectrometry for adherence monitoring.
Pu, Fan; Pandey, Sangeeta; Bushman, Lane R; Anderson, Peter L; Ouyang, Zheng; Cooks, R Graham.
Afiliação
  • Pu F; Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47907, USA.
  • Pandey S; Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47907, USA.
  • Bushman LR; Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Denver, 12850 East Montview Blvd., Aurora, CO, 80045, USA.
  • Anderson PL; Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Denver, 12850 East Montview Blvd., Aurora, CO, 80045, USA. peter.anderson@cuanschutz.edu.
  • Ouyang Z; Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47907, USA.
  • Cooks RG; Department of Precision Instrument, Tsinghua University, Haidian District, Beijing, 100084, China.
Anal Bioanal Chem ; 412(6): 1243-1249, 2020 Feb.
Article em En | MEDLINE | ID: mdl-31897555
ABSTRACT
Inadequate adherence to chronic medications is a far-reaching problem with financial and human health consequences. By a wide margin, non-adherence is the leading cause of therapeutic failures of HIV pre-exposure chemoprophylaxis (PrEP) and antiretroviral therapy (ART). It has been proven that HIV infection can be prevented by daily dosing of emtricitabine and tenofovir disoproxil fumarate. Measurement of intracellular tenofovir diphosphate in red blood cells has been established as an effective way to assess cumulative adherence, however, the LC-MS-based analytical method developed for the purpose is both complicated and expensive. Here, we report a simple method for adherence monitoring based on direct MS quantification of intracellular tenofovir diphosphate in human whole blood. The method requires only microliters of whole blood, employs special membranes to perform plasma separation and concomitant desalting during blood collection, and uses nanoelectrospray on a triple quadrupole instrument. Quantitative performance in this proof-of-concept study includes RSDs of < 15% and successful analysis of a small number of patient samples with medium to high adherence levels. The results correlate with those of a validated LC-MS/MS method, and an R2 value of 0.9962 is achieved. This methodology has promise for extension to point-of-care testing using miniature mass spectrometers. Graphical abstract.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Organofosfatos / Adenina / Fármacos Anti-HIV / Espectrometria de Massas em Tandem Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Organofosfatos / Adenina / Fármacos Anti-HIV / Espectrometria de Massas em Tandem Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Estados Unidos