Your browser doesn't support javascript.
loading
Performing IVIM-DWI using the multifunctional nanosystem for the evaluation of the antitumor microcirculation changes.
Gao, Peng; Liu, Yiyong; Shi, Changzheng; Liu, Yubao; Luo, Liangping.
Afiliação
  • Gao P; Medical Imaging Center, Shenzhen Hospital, Southern Medical University, Shenzhen, 518100, China.
  • Liu Y; Department of Radiology and Nuclear Medicine, People's Hospital of Yichun, Yichun, 336000, China.
  • Shi C; Medical Imaging Center, The First Affiliated Hospital of Jinan University, Guangzhou, 510630, China.
  • Liu Y; Medical Imaging Center, Shenzhen Hospital, Southern Medical University, Shenzhen, 518100, China. ybliu28@163.com.
  • Luo L; Medical Imaging Center, The First Affiliated Hospital of Jinan University, Guangzhou, 510630, China. tluolp@jnu.edu.cn.
MAGMA ; 33(4): 517-526, 2020 Aug.
Article em En | MEDLINE | ID: mdl-31897903
OBJECTIVES: There is a controversy about the D* and f values of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) for mid- and long-term efficacy monitoring of tumor blood perfusion. To monitor the antitumor efficacy of the F/A-PLGA@DOX/SPIO nanosystem via IVIM-DWI and to explore the value of parameters pseudo-diffusion (D*) and fraction of pseudo-diffusion (f) for evaluating therapeutic effect in non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: Thirty-six A549 tumor-bearing mice were divided randomly into three groups (each n = 12). Group 1 (G1) was injected with saline (the control group). Group 2 (G2) and group 3(G3) were injected with DOX and F/A-PLGA@DOX/SPIO, respectively. Each group underwent IVIM-DWI scanning at baseline and 3, 14, 21, and 28 days after treatment. D* and f values were derived using GE AW 4.5 post-processing station. All mice were sacrificed for pathological examination. RESULTS: The D* value of all three groups showed an upward trend, with the highest increase in G1 and the lowest in G3. Conversely, the f value of all groups trended to decrease within 7 days, of which G3 showed the most significant decline. Immunohistochemical staining revealed that vascular endothelial growth factor (VEGF)-positive staining rate and the microvessel density (MVD) of the tumors in G3 were significantly lower than those of the other groups (P < 0.05). The D* and f values were significantly and positively correlated to CD31 (r = 0.654, P < 0.001; r = 0.712, P < 0.001) and VEGF (r = 0.694, P < 0.001; r = 0.664, P < 0.001). CONCLUSION: IVIM-DWI-derived parameters D* and f are valuable indicators for the evaluation of the antitumor microcirculation changes of multifunctional nanosystem.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Carcinoma Pulmonar de Células não Pequenas / Imagem de Difusão por Ressonância Magnética / Neoplasias Pulmonares / Antineoplásicos Limite: Animals / Humans / Male Idioma: En Revista: MAGMA Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Carcinoma Pulmonar de Células não Pequenas / Imagem de Difusão por Ressonância Magnética / Neoplasias Pulmonares / Antineoplásicos Limite: Animals / Humans / Male Idioma: En Revista: MAGMA Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China