Your browser doesn't support javascript.
loading
Detection of cyprinid herpesvirus 2 by loop-mediated isothermal amplification in combination with a lateral flow dipstick.
Li, Yanli; Lin, Feng; Sun, Lihui; Huang, Aixia; Chen, Jianming; Hao, Guijie; Yuan, Xuemei; Zhang, Haiqi; Su, Shengqi.
Afiliação
  • Li Y; Key Laboratory of Freshwater Fish Reproduction and Development (Ministry of Education), College of Animal Science and Technology, Southwest University, Chongqing, 400715, PR China; Key Laboratory of Healthy Freshwater Aquaculture, Ministry of Agriculture, Zhejiang Institute of Freshwater Fisheries,
  • Lin F; Key Laboratory of Healthy Freshwater Aquaculture, Ministry of Agriculture, Zhejiang Institute of Freshwater Fisheries, Huzhou, 313001, China. Electronic address: wwlinfeng@163.com.
  • Sun L; Key Laboratory of Healthy Freshwater Aquaculture, Ministry of Agriculture, Zhejiang Institute of Freshwater Fisheries, Huzhou, 313001, China.
  • Huang A; Key Laboratory of Healthy Freshwater Aquaculture, Ministry of Agriculture, Zhejiang Institute of Freshwater Fisheries, Huzhou, 313001, China.
  • Chen J; Key Laboratory of Healthy Freshwater Aquaculture, Ministry of Agriculture, Zhejiang Institute of Freshwater Fisheries, Huzhou, 313001, China.
  • Hao G; Key Laboratory of Healthy Freshwater Aquaculture, Ministry of Agriculture, Zhejiang Institute of Freshwater Fisheries, Huzhou, 313001, China.
  • Yuan X; Key Laboratory of Healthy Freshwater Aquaculture, Ministry of Agriculture, Zhejiang Institute of Freshwater Fisheries, Huzhou, 313001, China.
  • Zhang H; Key Laboratory of Healthy Freshwater Aquaculture, Ministry of Agriculture, Zhejiang Institute of Freshwater Fisheries, Huzhou, 313001, China. Electronic address: zmk407@126.com.
  • Su S; Key Laboratory of Freshwater Fish Reproduction and Development (Ministry of Education), College of Animal Science and Technology, Southwest University, Chongqing, 400715, PR China. Electronic address: sushengqi@swu.edu.cn.
Mol Cell Probes ; 50: 101507, 2020 04.
Article em En | MEDLINE | ID: mdl-31911113
ABSTRACT
We developed a convenient technique to detect Herpesviral haematopoietic necrosis attributed to cyprinid herpes virus 2 (CyHV-2), a serious disease of Crucian carp and goldfish related to high mortality. In the present study, we employed a lateral flow dipstick (LAMP-LFD) to present a loop-mediated isothermal amplification assay. The specificity was ascertained via other six viruses, and the sensitivity was compared using PCR method, which are the reaction conditions changes for the method improved. The results revealed that CyHV-2 performance was observable at 64 °C in a separated tube within 60 min, when the samples hybridized using an FITC-labeled probe. As the LAMP-LFD method's specificity was high, with its sensitivity identical to that of traditional PCR, the overall DNA collected revealed the lowest detection limit of 0.18 pg/µl from goldfish diseased by CyHV-2. In summary, the development of LAMP-LFD's method does not require expensive instruments, and it can be regarded as a fast, simple, and reliable method for CyHV-2 detection.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reologia / Técnicas de Amplificação de Ácido Nucleico / Técnicas de Diagnóstico Molecular / Herpesviridae Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Mol Cell Probes Assunto da revista: BIOLOGIA MOLECULAR / BIOTECNOLOGIA Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reologia / Técnicas de Amplificação de Ácido Nucleico / Técnicas de Diagnóstico Molecular / Herpesviridae Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Mol Cell Probes Assunto da revista: BIOLOGIA MOLECULAR / BIOTECNOLOGIA Ano de publicação: 2020 Tipo de documento: Article