Your browser doesn't support javascript.
loading
Need for pacing in patients who qualify for an implantable cardioverter-defibrillator: Clinical implications for the subcutaneous ICD.
Kutyifa, Valentina; Rosero, Spencer Z; McNitt, Scott; Polonsky, Bronislava; Brown, Mary W; Zareba, Wojciech; Goldenberg, Ilan.
Afiliação
  • Kutyifa V; Heart Research Follow-Up Program, University of Rochester Medical Center, Rochester, NY, USA.
  • Rosero SZ; Heart Research Follow-Up Program, University of Rochester Medical Center, Rochester, NY, USA.
  • McNitt S; Heart Research Follow-Up Program, University of Rochester Medical Center, Rochester, NY, USA.
  • Polonsky B; Heart Research Follow-Up Program, University of Rochester Medical Center, Rochester, NY, USA.
  • Brown MW; Heart Research Follow-Up Program, University of Rochester Medical Center, Rochester, NY, USA.
  • Zareba W; Heart Research Follow-Up Program, University of Rochester Medical Center, Rochester, NY, USA.
  • Goldenberg I; Heart Research Follow-Up Program, University of Rochester Medical Center, Rochester, NY, USA.
Ann Noninvasive Electrocardiol ; 25(4): e12744, 2020 07.
Article em En | MEDLINE | ID: mdl-31994819
ABSTRACT

BACKGROUND:

Implantation of the subcutaneous implantable cardioverter-defibrillator (S-ICD) is spreading and has been shown to be safe and effective; however, it does not provide brady-pacing. Currently, data on the need for brady-pacing and cardiac resynchronization therapy (CRT) implantation in patients with ICD indication are limited.

METHODS:

The Multicenter Automatic Defibrillator Implantation Trial (MADIT)-II enrolled post-MI patients with reduced ejection fraction (EF ≤ 35%), randomized to either an implantable cardioverter-defibrillator (ICD) or conventional medical therapy. Kaplan-Meier analyses and multivariate Cox models were performed to assess the incidence and predictors of pacemaker (PM), or CRT implantation in the conventional arm of MADIT-II, after excluding 32 patients (6.5%) with a previously implanted PM.

RESULTS:

During the median follow-up of 20 months, 24 of 458 patients (5.2%) were implanted with a PM or a CRT (19 PM, 5 CRT). Symptomatic sinus bradycardia was the primary indication for PM implantation (n = 9, 37%), followed by AV block (n = 5, 21%), tachy-brady syndrome (n = 4, 17%), and carotid sinus hypersensitivity (n = 1, 4%). Baseline PR interval >200 ms (HR = 3.07, 95% CI 1.24-7.57, p = .02), and CABG before enrollment (HR = 6.88, 95% CI 1.58-29.84, p = .01) predicted subsequent PM/CRT implantation. Patients with PM/CRT implantation had a significantly higher risk for heart failure (HR = 2.67, 95% CI = 1.38-5.14, p = .003), but no increased mortality risk (HR = 1.06, 95% CI = 0.46-2.46, p = .89).

CONCLUSION:

The short-term need for ventricular pacing or CRT implantation in patients with MADIT-II ICD indication was low, especially in those with a normal baseline PR interval, and such patients are appropriate candidates for the subcutaneous ICD.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Desfibriladores Implantáveis / Terapia de Ressincronização Cardíaca / Cardiopatias Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ann Noninvasive Electrocardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Desfibriladores Implantáveis / Terapia de Ressincronização Cardíaca / Cardiopatias Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ann Noninvasive Electrocardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Estados Unidos