Nanoscale x-ray holotomography of human brain tissue with phase retrieval based on multienergy recordings.
Robisch, Anna-Lena; Eckermann, Marina; Töpperwien, Mareike; van der Meer, Franziska; Stadelmann, Christine; Salditt, Tim.
Afiliação
  • Robisch AL; Georg-August-Universität Göttingen, Institut für Röntgenphysik, Göttingen, Germany.
  • Eckermann M; Georg-August-Universität Göttingen, Institut für Röntgenphysik, Göttingen, Germany.
  • Töpperwien M; University of Göttingen, Cluster of Excellence "Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells," Göttingen, Germany.
  • van der Meer F; Georg-August-Universität Göttingen, Institut für Röntgenphysik, Göttingen, Germany.
  • Stadelmann C; Universitätsmedizin Göttingen, Institut für Neuropathologie, Klinik für Neurologie, Göttingen, Germany.
  • Salditt T; Universitätsmedizin Göttingen, Institut für Neuropathologie, Klinik für Neurologie, Göttingen, Germany.
J Med Imaging (Bellingham) ; 7(1): 013501, 2020 Jan.
Article em En | MEDLINE | ID: mdl-32016134
ABSTRACT
X-ray cone-beam holotomography of unstained tissue from the human central nervous system reveals details down to subcellular length scales. This visualization of variations in the electron density of the sample is based on phase-contrast techniques using intensities formed by self-interference of the beam between object and detector. Phase retrieval inverts diffraction and overcomes the phase problem by constraints such as several measurements at different Fresnel numbers for a single projection. Therefore, the object-to-detector distance (defocus) can be varied. However, for cone-beam geometry, changing defocus changes magnification, which can be problematic in view of image processing and resolution. Alternatively, the photon energy can be altered (multi-E). Far from absorption edges, multi-E data yield the wavelength-independent electron density. We present the multi-E holotomography at the Göttingen Instrument for Nano-Imaging with X-Rays (GINIX) setup of the P10 beamline at Deutsches Elektronen-Synchrotron. The instrument is based on a combined optics of elliptical mirrors and an x-ray waveguide positioned in the focal plane for further coherence, spatial filtering, and high numerical aperture. Previous results showed the suitability of this instrument for nanoscale tomography of unstained brain tissue. We demonstrate that upon energy variation, the focal spot is stable enough for imaging. To this end, a double-crystal monochromator and automated alignment routines are required. Three tomograms of human brain tissue were recorded and jointly analyzed using phase retrieval based on the contrast transfer function formalism generalized to multiple photon energies. Variations of the electron density of the sample are successfully reconstructed.