Your browser doesn't support javascript.
loading
Benchmarking tomographic acquisition schemes for high-resolution structural biology.
Turonová, Beata; Hagen, Wim J H; Obr, Martin; Mosalaganti, Shyamal; Beugelink, J Wouter; Zimmerli, Christian E; Kräusslich, Hans-Georg; Beck, Martin.
Afiliação
  • Turonová B; European Molecular Biology Laboratory, Structure and Computational Biology Unit, 69124, Heidelberg, Germany.
  • Hagen WJH; European Molecular Biology Laboratory, Structure and Computational Biology Unit, 69124, Heidelberg, Germany.
  • Obr M; Department of Infectious Diseases, Virology, Universitätsklinikum Heidelberg, 69120, Heidelberg, Germany.
  • Mosalaganti S; Institute of Science and Technology Austria, A-3400, Klosterneuburg, Austria.
  • Beugelink JW; European Molecular Biology Laboratory, Structure and Computational Biology Unit, 69124, Heidelberg, Germany.
  • Zimmerli CE; European Molecular Biology Laboratory, Structure and Computational Biology Unit, 69124, Heidelberg, Germany.
  • Kräusslich HG; Cryo-Electron Microscopy, Bijvoet Center for Biomolecular Research, Department of Chemistry, Faculty of Science, Utrecht University, 3584, CH Utrecht, The Netherlands.
  • Beck M; Crystal and Structural Chemistry, Bijvoet Center for Biomolecular Research, Department of Chemistry, Faculty of Science, Utrecht University, 3584 CH, Utrecht, The Netherlands.
Nat Commun ; 11(1): 876, 2020 02 13.
Article em En | MEDLINE | ID: mdl-32054835
Cryo electron tomography with subsequent subtomogram averaging is a powerful technique to structurally analyze macromolecular complexes in their native context. Although close to atomic resolution in principle can be obtained, it is not clear how individual experimental parameters contribute to the attainable resolution. Here, we have used immature HIV-1 lattice as a benchmarking sample to optimize the attainable resolution for subtomogram averaging. We systematically tested various experimental parameters such as the order of projections, different angular increments and the use of the Volta phase plate. We find that although any of the prominently used acquisition schemes is sufficient to obtain subnanometer resolution, dose-symmetric acquisition provides considerably better outcome. We discuss our findings in order to provide guidance for data acquisition. Our data is publicly available and might be used to further develop processing routines.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microscopia Crioeletrônica / Tomografia com Microscopia Eletrônica Tipo de estudo: Prognostic_studies Idioma: En Revista: Nat Commun Assunto da revista: BIOLOGIA / CIENCIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microscopia Crioeletrônica / Tomografia com Microscopia Eletrônica Tipo de estudo: Prognostic_studies Idioma: En Revista: Nat Commun Assunto da revista: BIOLOGIA / CIENCIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Alemanha