Your browser doesn't support javascript.
loading
Comparing the mechanical properties of a self-expandable metallic stent for colorectal obstruction: Proposed measurement method of axial force using a new measurement machine.
Sasaki, Takashi; Ishibashi, Rei; Yoshida, Shuntaro; Fujisawa, Toshio; Shinagawa, Hiroki; Gon, Chimyon; Nakai, Yousuke; Sasahira, Naoki; Saida, Yoshihisa; Isayama, Hiroyuki.
Afiliação
  • Sasaki T; Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan.
  • Ishibashi R; Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
  • Yoshida S; Department of Endoscopy and Endoscopic Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
  • Fujisawa T; Department of Gastroenterology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.
  • Shinagawa H; Medical Laboratory, Research & Development Center, Zeon Corporation, Toyama, Japan.
  • Gon C; Medical Laboratory, Research & Development Center, Zeon Corporation, Toyama, Japan.
  • Nakai Y; Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
  • Sasahira N; Department of Endoscopy and Endoscopic Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
  • Saida Y; Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan.
  • Isayama H; Department of Surgery, Toho University Ohashi Medical Center, Tokyo, Japan.
Dig Endosc ; 33(1): 170-178, 2021 Jan.
Article em En | MEDLINE | ID: mdl-32196766
ABSTRACT

OBJECTIVES:

Colorectal stenting is widely performed using self-expandable metallic stents (SEMSs), but the mechanical properties have not been evaluated. Therefore, we conducted an in vitro study to evaluate the mechanical properties of colorectal SEMSs.

METHODS:

Eighteen individual types and sizes of uncovered SEMSs were evaluated for their mechanical properties. Radial force was measured using a measurement machine. Axial force (AF) was measured by two

methods:

a conventional manual method and a new method using a measurement machine. The correlation of these two methods was evaluated. We also proposed an "AF zero border" that was defined as the angle at which the torque force disappeared.

RESULTS:

Radial force versus diameter curves and AF versus angle curves were influenced by the structure and the size of each stent. There was excellent correlation of AFs measured by the new and conventional manual method (y = 21.434x, R = 0.881, P < 0.0001). Colorectal SEMSs could be categorized into five subgroups according to the mechanical properties. Most hook-wired SEMSs had the AF of zero border.

CONCLUSIONS:

This is the first report to evaluate the mechanical properties of colorectal SEMSs, and these data may provide useful information for the clinical use and development of colorectal SEMS. Furthermore, the new measurement machine might standardize the measuring method of AF.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Colorretais / Stents Metálicos Autoexpansíveis Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: Dig Endosc Assunto da revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Colorretais / Stents Metálicos Autoexpansíveis Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: Dig Endosc Assunto da revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Japão