Your browser doesn't support javascript.
loading
A Method to Quantify Tensile Biaxial Properties of Mouse Aortic Valve Leaflets.
Chaparro, Daniel; Dargam, Valentina; Alvarez, Paulina; Yeung, Jay; Saytashev, Ilyas; Bustillo, Jenniffer; Loganathan, Archana; Ramella-Roman, Jessica; Agarwal, Arvind; Hutcheson, Joshua D.
Afiliação
  • Chaparro D; Department of Biomedical Engineering, Florida International University, Miami, FL 33174.
  • Dargam V; Department of Biomedical Engineering, Florida International University, Miami, FL 33174.
  • Alvarez P; Department of Biomedical Engineering, Florida International University, Miami, FL 33174.
  • Yeung J; Department of Biomedical Engineering, Florida International University, Miami, FL 33174.
  • Saytashev I; Department of Biomedical Engineering, Florida International University, Miami, FL 33174.
  • Bustillo J; Department of Mechanical and Materials Engineering, Florida International University, Miami, FL 33174.
  • Loganathan A; Department of Mechanical and Materials Engineering, Florida International University, Miami, FL 33174.
  • Ramella-Roman J; Department of Biomedical Engineering, Florida International University, Miami, FL 33174.
  • Agarwal A; Department of Mechanical and Materials Engineering, Florida International University, Miami, FL 33174.
  • Hutcheson JD; Department of Biomedical Engineering, Florida International University, Miami, FL 33174; Biomolecular Sciences Institute, Florida International University, Miami, FL 33199.
J Biomech Eng ; 142(10)2020 10 01.
Article em En | MEDLINE | ID: mdl-32291440
ABSTRACT
Understanding aortic valve (AV) mechanics is crucial in elucidating both the mechanisms that drive the manifestation of valvular diseases as well as the development of treatment modalities that target these processes. Genetically modified mouse models have become the gold standard in assessing biological mechanistic influences of AV development and disease. However, very little is known about mouse aortic valve leaflet (MAVL) tensile properties due to their microscopic size (∼500 µm long and 45 µm thick) and the lack of proper mechanical testing modalities to assess uniaxial and biaxial tensile properties of the tissue. We developed a method in which the biaxial tensile properties of MAVL tissues can be assessed by adhering the tissues to a silicone rubber membrane utilizing dopamine as an adhesive. Applying equiaxial tensile loads on the tissue-membrane composite and tracking the engineering strains on the surface of the tissue resulted in the characteristic orthotropic response of AV tissues seen in human and porcine tissues. Our data suggest that the circumferential direction is stiffer than the radial direction (n = 6, P = 0.0006) in MAVL tissues. This method can be implemented in future studies involving longitudinal mechanical stimulation of genetically modified MAVL tissues bridging the gap between cellular biological mechanisms and valve mechanics in popular mouse models of valve disease.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estresse Mecânico Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: J Biomech Eng Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estresse Mecânico Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: J Biomech Eng Ano de publicação: 2020 Tipo de documento: Article