Dynamics of a micro-electro-mechanical system associated with an atomic force microscope considering squeeze film damping.
Appl Opt
; 59(13): D76-D80, 2020 May 01.
Article
em En
| MEDLINE
| ID: mdl-32400627
In the following paper, we present a nonlinear model of an atomic force microscope considering the potential of Lennard-Jones and the nonlinear friction produced by the squeeze film damping effect, between the cantilever and the sample. Specifically, we study the existence and stability of periodic solutions using the lower and upper solution method in the system without friction. The condition for persistence of the homocline orbit was established by Melnikov method when the model has nonlinear friction. In this sense, the analytic and numerical approach is presented to verify the solutions of the model.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Tipo de estudo:
Risk_factors_studies
Idioma:
En
Revista:
Appl Opt
Ano de publicação:
2020
Tipo de documento:
Article