S-ICD lead dislodgement in a young isometric athlete: A rare complication.
Bissolino, Arianna; Andreis, Alessandro; Magnano, Massimo; Budano, Carlo; Castagno, Davide; Golzio, Pier Giorgio; Giustetto, Carla; De Ferrari, Gaetano Maria.
Afiliação
  • Bissolino A; Division of Cardiology, Department of Medical Sciences, Città della Salute e della Scienza di Torino Hospital, University of Turin, Torino, Italy.
  • Andreis A; Division of Cardiology, Department of Medical Sciences, Città della Salute e della Scienza di Torino Hospital, University of Turin, Torino, Italy.
  • Magnano M; Division of Cardiology, Department of Medical Sciences, Città della Salute e della Scienza di Torino Hospital, University of Turin, Torino, Italy.
  • Budano C; Division of Cardiology, Department of Medical Sciences, Città della Salute e della Scienza di Torino Hospital, University of Turin, Torino, Italy.
  • Castagno D; Division of Cardiology, Department of Medical Sciences, Città della Salute e della Scienza di Torino Hospital, University of Turin, Torino, Italy.
  • Golzio PG; Division of Cardiology, Department of Medical Sciences, Città della Salute e della Scienza di Torino Hospital, University of Turin, Torino, Italy.
  • Giustetto C; Division of Cardiology, Department of Medical Sciences, Città della Salute e della Scienza di Torino Hospital, University of Turin, Torino, Italy.
  • De Ferrari GM; Division of Cardiology, Department of Medical Sciences, Città della Salute e della Scienza di Torino Hospital, University of Turin, Torino, Italy.
Pacing Clin Electrophysiol ; 43(8): 898-900, 2020 08.
Article em En | MEDLINE | ID: mdl-32460376
ABSTRACT
The subcutaneous implantable cardioverter defibrillator (S-ICD) is an alternative to transvenous ICD in patients who do not need cardiac pacing. We report the case of a young isometric athlete who received S-ICD for primary prevention of sudden death. Lead dislodgement and myopotential noise oversensing during isometric training led to inappropriate shock, and a surgical revision was performed. During the procedure, strong fibrous adhesions were found, requiring polytetrafluoroethylene dilator sheaths. The S-ICD was finally reimplanted. Despite continued isometric training, no more myopotential oversensing occurred after 1-year follow-up. The present case highlights the possible higher risks of lead complication in an isometric athlete and the uncommon effort in removing an old-generation subcutaneous defibrillator lead.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Morte Súbita Cardíaca / Desfibriladores Implantáveis / Falha de Equipamento / Síndrome de Brugada Limite: Adult / Humans / Male Idioma: En Revista: Pacing Clin Electrophysiol Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Morte Súbita Cardíaca / Desfibriladores Implantáveis / Falha de Equipamento / Síndrome de Brugada Limite: Adult / Humans / Male Idioma: En Revista: Pacing Clin Electrophysiol Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Itália