Your browser doesn't support javascript.
loading
X-ray nano-tomography of complete scales from the ultra-white beetles Lepidiota stigma and Cyphochilus.
Burg, Stephanie L; Washington, Adam L; Villanova, Julie; Dennison, Andrew J C; McLoughlin, Daragh; Mykhaylyk, Oleksandr O; Vukusic, Pete; Furnass, Will; Jones, Richard A L; Parnell, Andrew J; Fairclough, J Patrick A.
Afiliação
  • Burg SL; Department of Physics and Astronomy, The University of Sheffield, Sheffield, S3 7RH, UK. s.l.burg@sheffield.ac.uk.
  • Washington AL; Department of Physics and Astronomy, The University of Sheffield, Sheffield, S3 7RH, UK.
  • Villanova J; ISIS Pulsed Neutron and Muon Source, Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Didcot, OX11 0QX, UK.
  • Dennison AJC; ID16B - ESRF - The European Synchrotron, CS 40220, 38043, Grenoble, Cedex 9, France.
  • McLoughlin D; Department of Physics and Astronomy, The University of Sheffield, Sheffield, S3 7RH, UK.
  • Mykhaylyk OO; Akzo-Nobel, Decorative Paints Research and Development, Slough, SL2 5DS, UK.
  • Vukusic P; Department of Chemistry, Dainton Building, The University of Sheffield, Sheffield, S3 7HF, UK.
  • Furnass W; School of Physics, Exeter University, Exeter, EX4 4QL, UK.
  • Jones RAL; Department of Computer Science, The University of Sheffield, Sheffield, S1 4DP, UK.
  • Parnell AJ; Department of Physics and Astronomy, The University of Sheffield, Sheffield, S3 7RH, UK.
  • Fairclough JPA; Department of Physics and Astronomy, The University of Sheffield, Sheffield, S3 7RH, UK.
Sci Data ; 7(1): 163, 2020 05 29.
Article em En | MEDLINE | ID: mdl-32472045
ABSTRACT
High resolution X-ray nano-tomography experiments are often limited to a few tens of micrometer size volumes due to detector size. It is possible, through the use of multiple overlapping tomography scans, to produce a large area scan which can encompass a sample in its entirety. Mounting and positioning regions to be scanned is highly challenging and normally requires focused ion beam approaches. In this work we have imaged intact beetle scale cells mounted on the tip of a needle using a micromanipulator stage. Here we show X-ray holotomography data for single ultra-white scales from the beetles Lepidiota stigma (L. stigma) and Cyphochilus which exhibit the most effective scattering of white light in the literature. The final thresholded matrices represent a scan area of 25 × 70 × 362.5 µm and 25 × 67.5 × 235µm while maintaining a pixel resolution of 25 nm. This tomographic approach allowed the internal structure of the scales to be captured completely intact and undistorted by the sectioning required for traditional microscopy techniques.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Besouros / Tomografia Computadorizada por Raios X / Imageamento Tridimensional / Exoesqueleto Limite: Animals Idioma: En Revista: Sci Data Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Besouros / Tomografia Computadorizada por Raios X / Imageamento Tridimensional / Exoesqueleto Limite: Animals Idioma: En Revista: Sci Data Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Reino Unido