Your browser doesn't support javascript.
loading
Delineation of whole heart and substructures in thoracic radiation therapy: National guidelines and contouring atlas by the Danish Multidisciplinary Cancer Groups.
Milo, Marie Louise Holm; Offersen, Birgitte Vrou; Bechmann, Troels; Diederichsen, Axel Cosmus Pyndt; Hansen, Christian Rønn; Holtved, Eva; Josipovic, Mirjana; Lörincz, Tamás; Maraldo, Maja Vestmø; Nielsen, Mette Holck; Nordsmark, Marianne; Nyström, Petra Witt; Pøhl, Mette; Rose, Hanne Krogh; Schytte, Tine; Yates, Esben Svitzer; Lorenzen, Ebbe Laugaard.
Afiliação
  • Milo MLH; Aarhus University Hospital, Department of Experimental Clinical Oncology, Aarhus, Denmark. Electronic address: maeols@rm.dk.
  • Offersen BV; Aarhus University Hospital, Department of Experimental Clinical Oncology, Aarhus, Denmark; Aarhus University Hospital, Department of Oncology, Aarhus, Denmark; Danish Centre for Particle Therapy, Aarhus, Denmark.
  • Bechmann T; Lillebaelt Hospital, University Hospital of Southern Denmark, Department of Oncology, Vejle, Denmark; Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark.
  • Diederichsen ACP; Odense University Hospital, Department of Cardiology, Odense, Denmark.
  • Hansen CR; Danish Centre for Particle Therapy, Aarhus, Denmark; Odense University Hospital, Laboratory of Radiation Physics, Odense, Denmark; University of Southern Denmark, Institute of Clinical Research, Odense, Denmark.
  • Holtved E; Odense University Hospital, Department of Oncology, Odense, Denmark.
  • Josipovic M; Rigshospitalet, Department of Oncology, Copenhagen University Hospital, Denmark.
  • Lörincz T; Aalborg University Hospital, Department of Oncology, Aalborg, Denmark.
  • Maraldo MV; Rigshospitalet, Department of Oncology, Copenhagen University Hospital, Denmark.
  • Nielsen MH; Odense University Hospital, Department of Oncology, Odense, Denmark.
  • Nordsmark M; Aarhus University Hospital, Department of Oncology, Aarhus, Denmark; Danish Centre for Particle Therapy, Aarhus, Denmark.
  • Nyström PW; Danish Centre for Particle Therapy, Aarhus, Denmark; Skandion Clinic, Uppsala, Sweden.
  • Pøhl M; Rigshospitalet, Department of Oncology, Copenhagen University Hospital, Denmark.
  • Rose HK; Aarhus University Hospital, Department of Oncology, Aarhus, Denmark.
  • Schytte T; Odense University Hospital, Department of Oncology, Odense, Denmark.
  • Yates ES; Danish Centre for Particle Therapy, Aarhus, Denmark; Aarhus University Hospital, Department of Medical Physics, Aarhus, Denmark.
  • Lorenzen EL; Danish Centre for Particle Therapy, Aarhus, Denmark; Odense University Hospital, Laboratory of Radiation Physics, Odense, Denmark.
Radiother Oncol ; 150: 121-127, 2020 09.
Article em En | MEDLINE | ID: mdl-32544606
ABSTRACT
BACKGROUND AND

PURPOSE:

This study presents Danish consensus guidelines for delineation of the heart and cardiac substructures across relevant Danish Multidisciplinary Cancer Groups. MATERIAL AND

METHODS:

Consensus guidelines for the heart and cardiac substructures were reached among 15 observers representing the radiotherapy (RT) committees of four Danish Multidisciplinary Cancer Groups. The guidelines were validated on CT scans of 12 patients, each with five independent contour sets. The Sørensen-Dice similarity coefficient (DSC), the distance between the centers of the arteries and the mean surface distance were used to evaluate the inter-observer variation.

RESULTS:

National guidelines for contouring the heart and cardiac substructures were achieved. The median DSC was 0.78-0.96 for the heart and the four cardiac chambers. For the four substructures of the left ventricle, the median DSC was 0.35-0.57. The coronary arteries were contoured in ten segments, with the best agreement for the left anterior descending coronary artery segments, with a median distance between the arteries ranging from 2.4-4.4 mm. The median variation was 3.7-12.8 mm for the right coronary artery segments and 3.7-6.2 mm for the left circumflex coronary artery segments, with the most pronounced inter-observer variation in the distal segment for all three coronary arteries.

CONCLUSION:

National guidelines for contouring the heart and cardiac substructures were developed across relevant Danish Multidisciplinary Cancer Groups, where RT dose to the heart is of concern. The inter-observer contour overlap was best for the heart and chambers and decreased for smaller structures.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Neoplasias Tipo de estudo: Guideline Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Radiother Oncol Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Neoplasias Tipo de estudo: Guideline Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Radiother Oncol Ano de publicação: 2020 Tipo de documento: Article