Your browser doesn't support javascript.
loading
A 2-Phase Merge Filter Approach to Computer-Aided Detection of Breast Tumors on 3-Dimensional Ultrasound Imaging.
Chiu, Ling-Ying; Kuo, Wen-Hung; Chen, Chiung-Nien; Chang, King-Jen; Chen, Argon.
Afiliação
  • Chiu LY; Institute of Industrial Engineering, National Taiwan University, Taipei, Taiwan.
  • Kuo WH; Department of Surgery, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei, Taiwan.
  • Chen CN; Department of Surgery, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei, Taiwan.
  • Chang KJ; Department of Surgery, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei, Taiwan.
  • Chen A; Institute of Industrial Engineering, National Taiwan University, Taipei, Taiwan.
J Ultrasound Med ; 39(12): 2439-2455, 2020 Dec.
Article em En | MEDLINE | ID: mdl-32567133
OBJECTIVES: The role of image analysis in 3-dimensional (3D) automated breast ultrasound (ABUS) images is increasingly important because of its widespread use as a screening tool in whole-breast examinations. However, reviewing a large number of images acquired from ABUS is time-consuming and sometimes error prone. The aim of this study, therefore, was to develop an efficient computer-aided detection (CADe) algorithm to assist the review process. METHODS: The proposed CADe algorithm consisted of 4 major steps. First, initial tumor candidates were formed by extracting and merging hypoechoic square cells on 2-dimensional (2D) transverse images. Second, a feature-based classifier was then constructed using 2D features to filter out nontumor candidates. Third, the remaining 2D candidates were merged longitudinally into 3D masses. Finally, a 3D feature-based classifier was used to further filter out nontumor masses to obtain the final detected masses. The proposed method was validated with 176 passes of breast images acquired by an Acuson S2000 automated breast volume scanner (Siemens Medical Solutions USA, Inc., Malvern, PA), including 44 normal passes and 132 abnormal passes containing 162 proven lesions (79 benign and 83 malignant). RESULTS: The proposed CADe system could achieve overall sensitivity of 100% and 90% with 6.71 and 5.14 false-positives (FPs) per pass, respectively. Our results also showed that the average number of FPs per normal pass (7.16) was more than the number of FPs per abnormal pass (6.56) at 100% sensitivity. CONCLUSIONS: The proposed CADe system has a great potential for becoming a good companion tool with ABUS imaging by ensuring high sensitivity with a relatively small number of FPs.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Ultrassonografia Mamária Tipo de estudo: Diagnostic_studies Limite: Female / Humans Idioma: En Revista: J Ultrasound Med Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Ultrassonografia Mamária Tipo de estudo: Diagnostic_studies Limite: Female / Humans Idioma: En Revista: J Ultrasound Med Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Taiwan