Your browser doesn't support javascript.
loading
Suboptimal Biological Sampling as a Probable Cause of False-Negative COVID-19 Diagnostic Test Results.
Kinloch, Natalie N; Ritchie, Gordon; Brumme, Chanson J; Dong, Winnie; Dong, Weiyan; Lawson, Tanya; Jones, R Brad; Montaner, Julio S G; Leung, Victor; Romney, Marc G; Stefanovic, Aleksandra; Matic, Nancy; Lowe, Christopher F; Brumme, Zabrina L.
Afiliação
  • Kinloch NN; Faculty of Health Sciences, Simon Fraser University, Burnaby, Canada.
  • Ritchie G; British Columbia Centre for Excellence in HIV/AIDS, Vancouver, Canada.
  • Brumme CJ; Division of Medical Microbiology and Virology, St. Paul's Hospital, Vancouver, Canada.
  • Dong W; Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, Canada.
  • Dong W; British Columbia Centre for Excellence in HIV/AIDS, Vancouver, Canada.
  • Lawson T; Department of Medicine, University of British Columbia, Vancouver, Canada.
  • Jones RB; British Columbia Centre for Excellence in HIV/AIDS, Vancouver, Canada.
  • Montaner JSG; British Columbia Centre for Excellence in HIV/AIDS, Vancouver, Canada.
  • Leung V; Division of Medical Microbiology and Virology, St. Paul's Hospital, Vancouver, Canada.
  • Romney MG; Infectious Diseases Division, Department of Medicine, Weill Cornell Medical College, New York, USA.
  • Stefanovic A; British Columbia Centre for Excellence in HIV/AIDS, Vancouver, Canada.
  • Matic N; Department of Medicine, University of British Columbia, Vancouver, Canada.
  • Lowe CF; Division of Medical Microbiology and Virology, St. Paul's Hospital, Vancouver, Canada.
  • Brumme ZL; Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, Canada.
J Infect Dis ; 222(6): 899-902, 2020 08 17.
Article em En | MEDLINE | ID: mdl-32594170
ABSTRACT
False-negative severe acute respiratory syndrome coronavirus 2 test results can negatively impact the clinical and public health response to coronavirus disease 2019 (COVID-19). We used droplet digital polymerase chain reaction (ddPCR) to demonstrate that human DNA levels, a stable molecular marker of sampling quality, were significantly lower in samples from 40 confirmed or suspected COVID-19 cases that yielded negative diagnostic test results (ie, suspected false-negative test results) compared with a representative pool of 87 specimens submitted for COVID-19 testing. Our results support suboptimal biological sampling as a contributor to false-negative COVID-19 test results and underscore the importance of proper training and technique in the collection of nasopharyngeal specimens.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pneumonia Viral / Manejo de Espécimes / Infecções por Coronavirus / Técnicas de Laboratório Clínico / Betacoronavirus Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: J Infect Dis Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pneumonia Viral / Manejo de Espécimes / Infecções por Coronavirus / Técnicas de Laboratório Clínico / Betacoronavirus Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: J Infect Dis Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Canadá