Your browser doesn't support javascript.
loading
Development of Facile and Selective Fluorescent Probe for Physiological Phosphates based on Aggregation-induced Emission.
Jiao, Zhe; Long, Xiaojuan; Lu, Yingfang; Guo, Zongning; Huang, Xuelin; Song, Chao.
Afiliação
  • Jiao Z; School of Environment and Civil Engineering, Dongguan University of Technology, Dongguan, 523808, China. jiaoz@dgut.edu.cn.
  • Long X; Dongguan thonebio. Co. Ltd, Dongguan, 523003, China. jiaoz@dgut.edu.cn.
  • Lu Y; Dongguan Environmental Monitoring Centre, 523009, Dongguan, China.
  • Guo Z; Dongguan Environmental Monitoring Centre, 523009, Dongguan, China.
  • Huang X; Integrated Technology Centre of Dongguan Entry-Exit Inspection and Quarantine Bureau, 523073, Dongguan, China.
  • Song C; Integrated Technology Centre of Dongguan Entry-Exit Inspection and Quarantine Bureau, 523073, Dongguan, China. 34056583@qq.com.
J Fluoresc ; 30(5): 1197-1202, 2020 Sep.
Article em En | MEDLINE | ID: mdl-32700171
ABSTRACT
In this work, two new fluorescence chemosensors 2-(4-(1,2,2-triphenylvinyl)phenoxy) acetic acid (TPE-COOH) and 2,2'-(((1,2-diphenylethane-1,2-diyl)bis(4,1-phenylene))bis(oxy))diacetic acid (TPE-(COOH)2) were synthesized and applied for the facile detection of physiological phosphates. Due to the aggregation-induced emission (AIE) character, the emission can be turned on after label free interaction with polyethyleneimine (PEI). When the physiological phosphates were introduced to the system, the AIEgens/PEI complex was dissociated due to stronger electrostatic interaction between PEI and phosphates, which resulted in the significant fluorescence quenching of AIEgens. As the four kinds of phosphates cytidine-5'-diphosphate disodium salt (CDP), adenosine-5 (ADP), sodium pyrophosphate (PPi) and guanosine-5'-diphosphate disodium salt (GDP) had different interaction with PEI, also the TPE-COOH and TPE-(COOH)2 had different interaction with PEI, the fluorescence quenching effect was distinct for four phosphates. The unique pattern of fluorescence variations was differentiated by chemometric methods including principal component analysis and linear discriminant analysis. The robustness of the sensor array was proved by discrimination of four kinds of phosphates in serum samples with different concentrations, and the discrimination capacity was not influenced in complicated samples Graphical abstract.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fosfatos / Corantes Fluorescentes / Acetatos Idioma: En Revista: J Fluoresc Assunto da revista: BIOFISICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fosfatos / Corantes Fluorescentes / Acetatos Idioma: En Revista: J Fluoresc Assunto da revista: BIOFISICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China