Your browser doesn't support javascript.
loading
Diagnostic performance of quantitative, semi-quantitative, and visual analysis of dynamic CT myocardial perfusion imaging: a validation study with invasive fractional flow reserve.
Li, Yuehua; Dai, Xu; Lu, Zhigang; Shen, Chengxing; Zhang, Jiayin.
Afiliação
  • Li Y; Institute of Diagnostic and Interventional Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Rd,, Shanghai, 200233, China.
  • Dai X; Institute of Diagnostic and Interventional Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Rd,, Shanghai, 200233, China.
  • Lu Z; Department of Cardiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Rd, Shanghai, China.
  • Shen C; Department of Cardiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Rd, Shanghai, China.
  • Zhang J; Institute of Diagnostic and Interventional Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Rd,, Shanghai, 200233, China. andrewssmu@msn.com.
Eur Radiol ; 31(1): 525-534, 2021 Jan.
Article em En | MEDLINE | ID: mdl-32794126
ABSTRACT

OBJECTIVES:

To investigate the diagnostic performance of absolute myocardial blood flow (MBF), MBFratio, and visual analysis of dynamic CT myocardial perfusion imaging (CT-MPI) for the detection of hemodynamically significant coronary stenosis.

METHODS:

Consecutive patients with chest pain and intermediate-to-high pre-test probability of obstructive coronary artery disease were prospectively enrolled. All patients were referred for dynamic CT-MPI and fractional flow reserve (FFR) measurements within 4 weeks. Absolute MBF, MBFratio (mean MBF of stenosis-subtended territories versus that of reference territories), and visually identified perfusion defect were tested for the diagnostic performance with reference to FFR.

RESULTS:

Sixty-two patients with 95 target vessels were included for final analysis. The mean radiation dose for dynamic CT-MPI was 3.0 (2.2-4.0) mSv. The mean lesion-based absolute MBF value was significantly lower in ischemic segments than that in non-ischemic segments (78.0 (65.0-86.0) mL/min/100 mL vs. 133.0 (117.5-163.8) mL/min/100 mL, p < 0.001). Similarly, the lesion-based MBFratio was also markedly lower in territories with positive FFR results (0.52 (0.44-0.64) vs. 0.93 (0.91-0.97), p < 0.001). According to per-lesion ROC curve analysis, MBF and MBFratio had a similar area under the curve (AUC) for detecting hemodynamically significant lesions (AUC = 0.942 vs. 0.956, p = 0.413), which were larger than that of visual analysis (AUC = 0.802, both p < 0.01). The vessel-based sensitivity, specificity, and diagnostic accuracy were 84.3%, 97.7%, and 90.5% for MBF and 96.1%, 93.2%, and 94.7% for MBFratio.

CONCLUSIONS:

Absolute MBF and MBFratio had similarly excellent diagnostic performance with reference to FFR. In addition, these two parameters outperformed visual analysis for the detection of myocardial ischemia. KEY POINTS • The mean MBF and MBFratio were significantly lower in ischemic segments than those in non-ischemic segments. • Absolute MBF and MBFratio had similar AUCs for the detection of hemodynamically significant lesions (AUC = 0.942 vs. 0.956, p = 0.413), which were larger than that of visual analysis (AUC = 0.802, both p < 0.01). • The vessel-based sensitivity, specificity, and diagnostic accuracy were 84.3%, 97.7%, and 90.5% for absolute MBF and 96.1%, 93.2%, and 94.7% for MBFratio.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Estenose Coronária / Reserva Fracionada de Fluxo Miocárdico / Imagem de Perfusão do Miocárdio Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Estenose Coronária / Reserva Fracionada de Fluxo Miocárdico / Imagem de Perfusão do Miocárdio Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China