Your browser doesn't support javascript.
loading
Nontargeted lipidomics of novel human plasma reference materials: hypertriglyceridemic, diabetic, and African-American.
Aristizabal-Henao, Juan J; Jones, Christina M; Lippa, Katrice A; Bowden, John A.
Afiliação
  • Aristizabal-Henao JJ; Department of Physiological Sciences, College of Veterinary Medicine, University of Florida, 1333 Center Drive, Gainesville, FL, 32610, USA.
  • Jones CM; Chemical Sciences Division, National Institutes of Standards and Technology, Gaithersburg, MD, 20899, USA.
  • Lippa KA; Chemical Sciences Division, National Institutes of Standards and Technology, Gaithersburg, MD, 20899, USA.
  • Bowden JA; Department of Physiological Sciences, College of Veterinary Medicine, University of Florida, 1333 Center Drive, Gainesville, FL, 32610, USA. john.bowden@ufl.edu.
Anal Bioanal Chem ; 412(27): 7373-7380, 2020 Nov.
Article em En | MEDLINE | ID: mdl-32851459
ABSTRACT
The unavailability of appropriate quality assurance/quality control materials in many lipidomics applications poses a significant challenge for lipidomics research. It is recommended that samples with certified values and/or consensus estimates, such as NIST SRM 1950-Metabolites in Frozen Human Plasma, be implemented in routine analyses to enable community-wide comparisons of lipidomics results and analytical workflows. Herein, we applied a nontargeted lipidomics method for the analysis of a new human plasma reference material suite developed by NIST (hypertriglyceridemic, diabetic, and African-American plasma pools), in addition to SRM 1950. We identified specific lipidomics fingerprints associated with each sample type, including lauric acid-containing lipids and elevated triacylglycerol levels in hypertriglyceridemic plasma, palmitoleic acid-containing lipids in diabetic plasma, and oxidized fatty acid-containing phospholipids in African-American plasma. This work highlights the importance of developing and profiling application-specific reference materials, while establishing reference data that may be used for system suitability and/or quality control metrics.Graphical abstract.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diabetes Mellitus / Lipidômica / Hiperglicemia / Lipídeos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diabetes Mellitus / Lipidômica / Hiperglicemia / Lipídeos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Estados Unidos