Your browser doesn't support javascript.
loading
Fast, direct and in situ monitoring of lipid oxidation in an oil-in-water emulsion by near infrared spectroscopy.
Daoud, Samar; Waschatko, Gustav; Bou-Maroun, Elias; Cayot, Philippe.
Afiliação
  • Daoud S; Unité Mixte "Procédés Alimentaires et Microbiologiques", Université Bourgogne Franche-Comté, AgroSup Dijon, PAM UMR A 02.102, F-21000 Dijon, France. samar.daoud@u-bourgogne.fr.
  • Waschatko G; Cargill R&D Centre Europe BVBA, Havenstraat 84, B-1800 Vilvoorde, Belgium.
  • Bou-Maroun E; Unité Mixte "Procédés Alimentaires et Microbiologiques", Université Bourgogne Franche-Comté, AgroSup Dijon, PAM UMR A 02.102, F-21000 Dijon, France. samar.daoud@u-bourgogne.fr.
  • Cayot P; Unité Mixte "Procédés Alimentaires et Microbiologiques", Université Bourgogne Franche-Comté, AgroSup Dijon, PAM UMR A 02.102, F-21000 Dijon, France. samar.daoud@u-bourgogne.fr.
Anal Methods ; 12(24): 3098-3105, 2020 06 26.
Article em En | MEDLINE | ID: mdl-32930169
Lipid oxidation has implications on food, cosmetics and other fat containing products. Fatty acid autoxidation alters both the quality and safety of these products. Efficient and fast methods are needed to track lipid oxidation in complex systems. In this study, an oil-in-water emulsion (20% v/v of fish oil stabilized with high oleic sunflower lecithin) was subjected to iron-initiated oxidation. Conjugated dienes (CDs) were measured after fat extraction using a standardized method. Near infrared spectroscopy (NIRS) has been used to record chemical changes occurring during oxidation directly in the emulsion. Variations were noticed in different spectral regions. Partial least squares regression (PLSR) revealed correlations between conjugated diene values and NIRS spectra. High coefficients of determination (R2 = 0.967 and 0.996) were found for calibration and prediction respectively. The CD value was predicted from NIRS spectra with an error of 7.26 mmol eq. LH kg-1 oil (7.8% error). Limits of detection (LOD) and quantification (LOQ) of 4.65 and 15.5 mmol eq. LH kg-1 oil were estimated. NIRS is a rapid and simple method for measuring lipid oxidation (CD value) in an emulsion without prior fat extraction. NIRS can replace the reference methods that use hazardous solvents and consume time. Therefore, NIRS enables in-line monitoring for process and quality control.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectroscopia de Luz Próxima ao Infravermelho / Ácidos Graxos Idioma: En Revista: Anal Methods Ano de publicação: 2020 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectroscopia de Luz Próxima ao Infravermelho / Ácidos Graxos Idioma: En Revista: Anal Methods Ano de publicação: 2020 Tipo de documento: Article País de afiliação: França