Safety and Efficacy of Scleral Lenses for Keratoconus.
Fuller, Daniel G; Wang, Yueren.
Afiliação
  • Fuller DG; Southern College of Optometry, Memphis, Tennessee.
Optom Vis Sci ; 97(9): 741-748, 2020 09.
Article em En | MEDLINE | ID: mdl-32932400
ABSTRACT

SIGNIFICANCE:

This study affirms the long-term safety and efficacy of scleral contact lens use in patients with keratoconus.

PURPOSE:

This study aimed to evaluate the safety and efficacy of contemporary scleral contact lenses in the visual rehabilitation of the keratoconic population.

METHODS:

A retrospective study of keratoconic subjects examined between 2013 and 2018 was conducted. Subjects were included regardless of age, sex, pre-existing morbidity, or scleral lens design. Only eyes fit successfully with scleral contact lenses for ≥1 year were included. Exclusion criteria were prior corneal surgery, dystrophy, degeneration, and trauma.

RESULTS:

A total of 157 eyes of 86 subjects met the study criteria. The mean Keratoconus Severity Score at initial fitting was 3.6 ± 1.0. Lenses were gas-permeable and nonfenestrated, with a mean overall diameter of 15.8 ± 0.6 mm and 70.1% toric scleral periphery. Physiological adverse events occurred in 9.6% of eyes, including microbial keratitis (0.6%), phlyctenulosis (0.6%), corneal abrasion (1.3%), contact lens-induced acute red eye (1.3%), corneal infiltrative events (1.3%), pingueculitis (1.3%), and hydrops (3.2%). Lens-related adverse events were documented in 55.4% of eyes. Adverse events related to surface issues included poor wetting in 1.9%, handling in 3.8%, reservoir fogging in 7.0%, lens intolerance in 7.6%, deposit in 8.9%, and broken lenses in 26.1% of eyes. The most common management strategies involved refits (54.0% of interventions), patient reeducation (29.5%), medical treatment (5.5%), surgical referral (6.8%), adjustment to wear time (2.5%), surface treatment (1.2%), and lens replacement (0.6%). Best-corrected distance logMAR visual acuity improved significantly from a mean of 0.50 in spectacles to a mean of 0.08 in scleral lenses (P < .0001). During the study period, 14.6% of eyes lost best-corrected scleral lens visual acuity, all from keratoconus progression.

CONCLUSIONS:

Consistent with other groups, our study demonstrates excellent safety and efficacy of scleral contact lenses in subjects with keratoconus.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Esclera / Lentes de Contato / Ceratocone Tipo de estudo: Observational_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Optom Vis Sci Assunto da revista: OPTOMETRIA Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Esclera / Lentes de Contato / Ceratocone Tipo de estudo: Observational_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Optom Vis Sci Assunto da revista: OPTOMETRIA Ano de publicação: 2020 Tipo de documento: Article