Impact of Preprocedural Aortic Valve Calcification on Conduction Disturbances after Transfemoral Aortic Valve Replacement.
Stachon, Peter; Steinfurt, Johannes; van de Loo, Tim; Trolese, Luca; Faber, Thomas; Kaier, Klaus; Heidt, Timo; Bothe, Wolfgang; Krauss, Tobias; Wolf, Dennis; Duerschmied, Daniel; Zehender, Manfred; Bamberg, Fabian; Bode, Christoph; von Zur Mühlen, Constantin.
Afiliação
  • Stachon P; University Heart Center Freiburg, Department of Cardiology and Angiology I, Faculty of Medicine, University of Freiburg, Freiburg, Germany, peter.stachon@universitaets-herzzentrum.de.
  • Steinfurt J; University Heart Center Freiburg, Department of Cardiology and Angiology I, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • van de Loo T; University Heart Center Freiburg, Department of Cardiology and Angiology I, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Trolese L; University Heart Center Freiburg, Department of Cardiology and Angiology I, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Faber T; University Heart Center Freiburg, Department of Cardiology and Angiology I, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Kaier K; Institute of Medical Biometry and Medical Informatics, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Heidt T; University Heart Center Freiburg, Department of Cardiology and Angiology I, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Bothe W; University Heart Center Freiburg, Department of Cardiovascular Surgery, Medical Faculty, University of Freiburg, Freiburg, Germany.
  • Krauss T; University Hospital Freiburg, Department of Radiology, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Wolf D; University Heart Center Freiburg, Department of Cardiology and Angiology I, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Duerschmied D; University Heart Center Freiburg, Department of Cardiology and Angiology I, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Zehender M; University Heart Center Freiburg, Department of Cardiology and Angiology I, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Bamberg F; University Hospital Freiburg, Department of Radiology, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Bode C; University Heart Center Freiburg, Department of Cardiology and Angiology I, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • von Zur Mühlen C; University Heart Center Freiburg, Department of Cardiology and Angiology I, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Cardiology ; 146(2): 228-237, 2021.
Article em En | MEDLINE | ID: mdl-32966978
ABSTRACT

AIM:

The present study analyzes in depth the impact of different calcification patterns on disturbances of the conduction system in transcatheter aortic valve replacement (TAVR) patients. METHODS AND

RESULTS:

A total of 169 preprocedural TAVR multislice computed tomography scans from consecutive transfemoral (TF) TAVRs performed between 2014 and 2017 using either Edwards SAPIEN or Medtronic Evolut R valves were retrospectively evaluated. The volume, distribution, and orientation of annular and valvular aortic valve calcification were measured and their impact on postoperative conduction disturbances was determined using linear and logistic regression analyses. The total volume of calcification and distribution at the aortic annulus or valve did not influence the conduction system. Oval calcification of the left aortic cusp was independently associated with an elevated risk for an increase in atrioventricular block degree (+0.6, p = 0.03). Moreover, orthogonal calcifications at the level of the aortic annulus were associated with an increased risk for QRS prolongation (+26 ms, p = 0.004) and an increased risk for permanent pacemaker implantation (OR 4.3, p = 0.03) after TF TAVR. This was more pronounced in patients undergoing TF TAVR using a balloon-expandable Edwards SAPIEN 3 valve (QRS +38.195 ms, p < 0.001; OR permanent pacemaker 15.48, p = 0.013).

CONCLUSION:

Orthogonal annular calcification confers an increased risk for conduction disturbances after TAVR. This is even more pronounced after implantation of balloon-expandable valves.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Substituição da Valva Aórtica Transcateter Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Cardiology Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Substituição da Valva Aórtica Transcateter Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Cardiology Ano de publicação: 2021 Tipo de documento: Article