Your browser doesn't support javascript.
loading
Salting-out assisted liquid-liquid extraction method optimized by design of experiments for the simultaneous high-performance liquid chromatography analysis of perampanel and stiripentol in mouse matrices.
Meirinho, Sara; Campos, Gonçalo; Rodrigues, Márcio; Fortuna, Ana; Falcão, Amílcar; Alves, Gilberto.
Afiliação
  • Meirinho S; CICS-UBI - Health Sciences Research Center, University of Beira Interior, Covilhã, Portugal.
  • Campos G; CICS-UBI - Health Sciences Research Center, University of Beira Interior, Covilhã, Portugal.
  • Rodrigues M; CICS-UBI - Health Sciences Research Center, University of Beira Interior, Covilhã, Portugal.
  • Fortuna A; UDI-IPG - Research Unit for Inland Development, Polytechnic Institute of Guarda, Guarda, Portugal.
  • Falcão A; Laboratory of Pharmacology, Faculty of Pharmacy, University of Coimbra, Coimbra, Portugal.
  • Alves G; CIBIT/ICNAS - Coimbra Institute for Biomedical Imaging and Translational Research, University of Coimbra, Coimbra, Portugal.
J Sep Sci ; 43(23): 4289-4304, 2020 Dec.
Article em En | MEDLINE | ID: mdl-32997431
ABSTRACT
We report a high-performance liquid chromatography method development able to simultaneously determine perampanel and stiripentol, two third-generation antiepileptics whose therapeutic spectrum can potentially be extended, in several mouse matrices. A salting-out assisted liquid-liquid extraction optimized by a design of experiments approach was adopted for sample preparations. Isopropanol and magnesium sulfate were the extraction solvent and salting-out agent, respectively. Both drugs and internal standard (terbinafine) were separated using a LiChroCART® Purospher Star column (C18 , 55 × 4 mm; 3 µm) isocratically pumped with mobile phase [1% triethylamine in water (pH 2.5) and acetonitrile (5347, v/v)] at 1 mL/min. Stiripentol and terbinafine were detected by fluorescence at 254/372 nm and perampanel at 275/430 nm. Good linearity was demonstrated for perampanel at 1-500 ng/mL range in brain, 2-2000 ng/mL in liver and 1-2000 ng/mL in plasma and kidney (r2  ≥ 0.9922), and for stiripentol between 10 and 2000 ng/mL in brain and 10 and 20 000 ng/mL in the remaining matrices (r2  ≥ 0.9917). Precision (CV ≤ 15%) and accuracy (bias ±15%) were also verified, with obtained recovery values consistent with those predicted by the experimental design. This method was applied in preliminary pharmacokinetic studies to quantify perampanel or stiripentol after oral administration to mice, showing to be a promising bioanalytical tool to support future nonclinical in vivo pharmacokinetic studies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Piridonas / Cloreto de Sódio / Dioxolanos / Extração Líquido-Líquido / Anticonvulsivantes Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: J Sep Sci Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Portugal

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Piridonas / Cloreto de Sódio / Dioxolanos / Extração Líquido-Líquido / Anticonvulsivantes Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: J Sep Sci Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Portugal