Your browser doesn't support javascript.
loading
Mass Spectrometry as a Highly Sensitive Method for Specific Circulating Tumor DNA Analysis in NSCLC: A Comparison Study.
Lamy, Pierre-Jean; van der Leest, Paul; Lozano, Nicolas; Becht, Catherine; Duboeuf, Frédérique; Groen, Harry J M; Hilgers, Werner; Pourel, Nicolas; Rifaela, Naomi; Schuuring, Ed; Alix-Panabières, Catherine.
Afiliação
  • Lamy PJ; Biopathologie et Génétique des Cancers, Institute d'Analyse Médicale Imagenome, Inovie, 6 Rue Fontenille, 34000 Montpellier, France.
  • van der Leest P; Department of Pathology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands.
  • Lozano N; Biopathologie et Génétique des Cancers, Institute d'Analyse Médicale Imagenome, Inovie, 6 Rue Fontenille, 34000 Montpellier, France.
  • Becht C; Oncologie Médicale, Clinique Clémenville, 25 rue Clémenville, 34000 Montpellier, France.
  • Duboeuf F; Oncologie Médicale, Clinique Clémenville, 25 rue Clémenville, 34000 Montpellier, France.
  • Groen HJM; Department of Pulmonary Medicine, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands.
  • Hilgers W; Oncologie Médicale, Institute Sainte Catherine, 250 Chemin de Baigne Pieds, 84918 Avignon, France.
  • Pourel N; Oncologie Médicale, Institute Sainte Catherine, 250 Chemin de Baigne Pieds, 84918 Avignon, France.
  • Rifaela N; Department of Pathology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands.
  • Schuuring E; Department of Pathology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands.
  • Alix-Panabières C; Laboratoire de Cellules Rares Circulantes, University Medical Center of Montpellier, 641, Avenue du Doyen Gaston GIRAUD, 34093 Montpellier, France.
Cancers (Basel) ; 12(10)2020 Oct 16.
Article em En | MEDLINE | ID: mdl-33081150
ABSTRACT
Plasma-based tumor mutational profiling is arising as a reliable approach to detect primary and therapy-induced resistance mutations required for accurate treatment decision making. Here, we compared the FDA-approved Cobas® EGFR Mutation Test v2 with the UltraSEEK™ Lung Panel on the MassARRAY® System on detection of EGFR mutations, accompanied with preanalytical sample assessment using the novel Liquid IQ® Panel. 137 cancer patient-derived cell-free plasma samples were analyzed with the Cobas® and UltraSEEK™ tests. Liquid IQ® analysis was initially validated (n = 84) and used to determine ccfDNA input for all samples. Subsequently, Liquid IQ® results were applied to harmonize ccfDNA input for the Cobas® and UltraSEEK™ tests for 63 NSCLC patients. The overall concordance between the Cobas® and UltraSEEK™ tests was 86%. The Cobas® test detected more EGFR exon19 deletions and L858R mutations, while the UltraSEEK™ test detected more T790M mutations. A 100% concordance in both the clinical (n = 137) and harmonized (n = 63) cohorts was observed when >10 ng of ccfDNA was used as determined by the Liquid IQ® Panel. The Cobas® and UltraSEEK™ tests showed similar sensitivity in EGFR mutation detection, particularly when ccfDNA input was sufficient. It is recommended to preanalytically determine the ccfDNA concentration accurately to ensure sufficient input for reliable interpretation and treatment decision making.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Cancers (Basel) Ano de publicação: 2020 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Cancers (Basel) Ano de publicação: 2020 Tipo de documento: Article País de afiliação: França