Your browser doesn't support javascript.
loading
Rapid and visual detection of Cd2+ based on aza-BODIPY near infrared dye and its application in real and biological samples for environmental contamination screening.
Piyanuch, Pornthip; Patawanich, Pramsak; Sirirak, Jitnapa; Suwatpipat, Kullatat; Kamkaew, Anyanee; Burgess, Kevin; Wanichacheva, Nantanit.
Afiliação
  • Piyanuch P; Department of Chemistry, Faculty of Science, Silpakorn University, Nakhon Pathom, 73000, Thailand.
  • Patawanich P; Department of Chemistry, Faculty of Science, Silpakorn University, Nakhon Pathom, 73000, Thailand.
  • Sirirak J; Department of Chemistry, Faculty of Science, Silpakorn University, Nakhon Pathom, 73000, Thailand.
  • Suwatpipat K; Department of Chemistry, Faculty of Science, Silpakorn University, Nakhon Pathom, 73000, Thailand.
  • Kamkaew A; School of Chemistry, Institute of Science, Suranaree University of Technology, Nakhon Ratchasima, 30000, Thailand.
  • Burgess K; Department of Chemistry, Texas A & M University, Box 30012, College Station, TX 77842, USA.
  • Wanichacheva N; Department of Chemistry, Faculty of Science, Silpakorn University, Nakhon Pathom, 73000, Thailand. Electronic address: wanichacheva_n@su.ac.th.
J Hazard Mater ; 409: 124487, 2021 05 05.
Article em En | MEDLINE | ID: mdl-33199148
ABSTRACT
Cadmium highly toxic and hazardous, and it can adversely affect human health leading to serious disorders. Herein, a water-soluble near-infrared sensor based on aza-BODIPY (1) was developed for dual determination of Cd2+ in environmental and biological media. This sensor exhibited color change from colorless to green along with a fluorescence enhancement in the near-infrared (NIR) region via photoinduced electron transfer (PET) after complexation with Cd2+. Sensor 1 can be employed in aqueous media at physiological pH for quantitative monitoring. It shows rapid response with high sensitivity (detection limit of 2.8 ppb; linear correlation over [Cd2+] 1.33 - 6.67 µM) and selectivity over potentially interfering ions. NIR sensor 1 can be used to determine [Cd2+] in living cells and environmental samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cádmio / Corantes Fluorescentes Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Humans Idioma: En Revista: J Hazard Mater Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Tailândia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cádmio / Corantes Fluorescentes Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Humans Idioma: En Revista: J Hazard Mater Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Tailândia