Your browser doesn't support javascript.
loading
Quantitation using HRMS: A new tool for rapid, specific and sensitive determination of catecholamines and deconjugated methanephrines metanephrines in urine.
Lefeuvre, S; Bois-Maublanc, J; Mongeois, E; Policarpo, V; Formaux, L; Francia, T; Billaud, E M; Got, L.
Afiliação
  • Lefeuvre S; Laboratory of Biochemistry, CHR Orléans, France. Electronic address: sandrine.lefeuvre@chu-poitiers.fr.
  • Bois-Maublanc J; Laboratory of Biochemistry, CHR Orléans, France.
  • Mongeois E; Diabetology - Endocrinology - Nutrition Department, CHR Orléans, France.
  • Policarpo V; Laboratory of Biochemistry, CHR Orléans, France.
  • Formaux L; Laboratory of Biochemistry, CHR Orléans, France.
  • Francia T; Laboratory of Biochemistry, CHR Orléans, France.
  • Billaud EM; Pharmacology Department, AP-HP, Hôpital Européen Georges Pompidou, Paris Descartes University, Paris, France.
  • Got L; Laboratory of Biochemistry, CHR Orléans, France.
Article em En | MEDLINE | ID: mdl-33246878
ABSTRACT
Urinary catecholamines and their methylated metabolites are biochemical indicators of pheochromocytoma, paraganglioma and neuroblastoma. A rapid and precise analytical method based on solid-phase extraction (SPE) and liquid chromatography separation coupled to high-resolution mass spectrometry (LC-HRMS) was developed and validated to measure urinary catecholamines (epinephrine (E), norepinephrine (NorE), dopamine (D)) and total methylated metabolites (normetanephrine (NorMN), metanephrine(MN) and 3-methoxytyramine (3-MT)) in a clinical setting. Results of 51 urine specimens measured using this LC-HRMS method were compared with a liquid chromatography assay with electrochemical detection (LC-EC). Urine samples (200 µL) were spiked with an internal standard solution followed by SPE purification. In the case of total methylated metabolites, urine was hydrolyzed before SPE purification. Separation was achieved on an Acclaim Mixed Mode WCX column, with an 8.5 min runtime. All compounds were detected in electrospray positive ionization mode with a parallel reaction monitoring acquisition and quantified with a linear regression (r2 > 0.998) between 2 and 200 µg/L (10.9-1090; 11.8-1182 nmol/L) for E and NorE respectively and between 10 and 1000 µg/L for others (65.2-6520; 50.7-5070; 54.5-5450 ; 59.8-5980 nmol/L for D, M, NorMN and 3-MT, respectively). Overall imprecision and bias did not exceed 15%. No significant matrix effect was observed. Correlation between the two assays was good except for epinephrine. Epinephrine concentrations measured by LC-EC method were slightly higher than values obtained with LC-HRMS method but without impact on clinical decision. This LC-HRMS assay provides a new tool for simultaneous quantitative catecholamine determination and was successfully applied in routine for the screening or follow up of pheochromocytoma, paraganglioma and neuroblastoma. LC-HRMS method offers significant advantages compared to LC-EC with good sensitivity, an unambiguous analyte determination and high sample throughput.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Catecolaminas / Metanefrina / Cromatografia Líquida Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Catecolaminas / Metanefrina / Cromatografia Líquida Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2021 Tipo de documento: Article