Your browser doesn't support javascript.
loading
Volumetric Capnography Monitoring and Effects of Epinephrine on Volume of Carbon Dioxide Elimination during Resuscitation after Cardiac Arrest in a Swine Pediatric Ventricular Fibrillatory Arrest.
Al-Subu, Awni M; Hacker, Timothy A; Eickhoff, Jens C; Ofori-Amanfo, George; Eldridge, Marlowe W.
Afiliação
  • Al-Subu AM; Division of Pediatric Critical Care Medicine, Department of Pediatrics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, United States.
  • Hacker TA; Cardiovascular Research Center, Department of Medicine, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, United States.
  • Eickhoff JC; Department of Biostatistics, University of Wisconsin, Madison, Wisconsin, United States.
  • Ofori-Amanfo G; Division of Pediatric Critical Care Medicine, Department of Pediatrics, Icahn School of Medicine at Mount Sinai, Mount Sinai Kravis Children's Hospital, New York, United States.
  • Eldridge MW; Division of Pediatric Critical Care Medicine, Department of Pediatrics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, United States.
J Pediatr Intensive Care ; 10(1): 31-37, 2021 Mar.
Article em En | MEDLINE | ID: mdl-33585059
The aim of this study was to examine the use of volumetric capnography monitoring to assess cardiopulmonary resuscitation (CPR) effectiveness by correlating it with cardiac output (CO), and to evaluate the effect of epinephrine boluses on both end-tidal carbon dioxide (EtCO 2 ) and the volume of CO 2 elimination (VCO 2 ) in a swine ventricular fibrillation cardiac arrest model. Planned secondary analysis of data collected to investigate the use of noninvasive monitors in a pediatric swine ventricular fibrillation cardiac arrest model was performed. Twenty-eight ventricular fibrillatory arrests with open cardiac massage were conducted. During CPR, EtCO 2 and VCO 2 had strong correlation with CO, measured as a percentage of baseline pulmonary blood flow, with correlation coefficients of 0.83 ( p < 0.001) and 0.53 ( p = 0.018), respectively. However, both EtCO 2 and VCO 2 had weak and nonsignificant correlation with diastolic blood pressure during CPR 0.30 ( p = 0.484) (95% confidence interval [CI], -0.51-0.83) and 0.25 ( p = 0.566) (95% CI, -0.55-0.81), respectively. EtCO 2 and VCO 2 increased significantly after the first epinephrine bolus without significant change in CO. The correlations between EtCO 2 and VCO 2 and CO were weak 0.20 ( p = 0.646) (95% CI, -0.59-0.79), and 0.27 ( p = 0.543) (95% CI, -0.54-0.82) following epinephrine boluses. Continuous EtCO 2 and VCO 2 monitoring are potentially useful metrics to ensure effective CPR. However, transient epinephrine administration by boluses might confound the use of EtCO 2 and VCO 2 to guide chest compression.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Pediatr Intensive Care Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Pediatr Intensive Care Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos