Your browser doesn't support javascript.
loading
Improved Uranium Isotope Ratio Analysis in Liquid Sampling-Atmospheric Pressure Glow Discharge/Orbitrap FTMS Coupling through the Use of an External Data Acquisition System.
Bills, Jacob R; Nagornov, Konstantin O; Kozhinov, Anton N; Williams, Tyler J; Tsybin, Yury O; Marcus, R Kenneth.
Afiliação
  • Bills JR; Department of Chemistry, Clemson University, Clemson, South Carolina 29634, United States.
  • Nagornov KO; Spectroswiss, 1015 Lausanne, Switzerland.
  • Kozhinov AN; Spectroswiss, 1015 Lausanne, Switzerland.
  • Williams TJ; Department of Chemistry, Clemson University, Clemson, South Carolina 29634, United States.
  • Tsybin YO; Spectroswiss, 1015 Lausanne, Switzerland.
  • Marcus RK; Department of Chemistry, Clemson University, Clemson, South Carolina 29634, United States.
J Am Soc Mass Spectrom ; 32(5): 1224-1236, 2021 May 05.
Article em En | MEDLINE | ID: mdl-33793219
Isotope ratio (IR) analysis of natural abundance uranium presents a formidable challenge for mass spectrometry (MS): the required spectral dynamic range needs to enable the quantitatively accurate measurement of the 234UO2 species present at ∼0.0053% isotopic abundance. We address this by empowering a benchtop Orbitrap Fourier transform mass spectrometer (FTMS) coupled with the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ion source and an external high-performance data acquisition system, FTMS Booster X2. The LS-APGD microplasma has demonstrated impressive capabilities regarding elemental and IR analysis when coupled with Orbitrap FTMS. Despite successes, there are limitations regarding the dynamic range and mass resolution that stem from space charge effects and data acquisition and processing restrictions. To overcome these limitations, the FTMS Booster was externally interfaced to an LS-APGD Q Exactive Focus Orbitrap FTMS to obtain time-domain signals (transients) and to process unreduced data. The unreduced time-domain data acquisition with user-controlled processing permit the evaluation of the effects of in-hardware transient phasing, increased transient lengths, advanced transient coadding, varying the length of a transient to be processed with a user-defined time increment, and the use of absorption-mode FT (aFT) processing methods on IR analysis. The added capabilities extend the spectral dynamic range of the instrument to at least 4-5 orders of magnitude and provide a resolution improvement from ∼70k to 900k m/Δm at 200 m/z. The empowered LS-APGD Orbitrap platform allows for the simultaneous measurement of 234UO2 and the prominent 235UO2 and 238UO2 isotopic species at their natural abundances, ultimately yielding improvements in performance when compared to previous uranium IR results on this same Q Exactive Focus instrument.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Am Soc Mass Spectrom Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Am Soc Mass Spectrom Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos